EVS-EN 13523-15:2015

Coil coated metals - Test methods - Part 15: Metamerism

General information
Withdrawn from 01.11.2021
Base Documents
EN 13523-15:2015
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.11.2021
Main
05.08.2015
Main
01.11.2002
Main
EVS-EN 13523-15:2002
This Part of EN 13523 defines terms of the procedure for determining the metamerism of a colour match of an organic coating on a metallic substrate.
When two colour specimens have identical spectral reflection curves, they are matching under any illuminant irrespective of its spectral characteristics. This is termed a "spectral match". It is also possible for two colour specimens having different spectral reflection curves to match visually under a given light source but not to match under another light source with different spectral characteristics; such matches are termed "metameric".
One quantitative description of metamerism is the so-called "metamerism index".
The information of the metamerism index is of limited value where E (instrumental colour difference for a given illuminant, see EN 13523-3:2001) is > 0,5. The metamerism index is not suited for determining the absolute colour difference or colour constancy of a given specimen at change of illuminant.
The colour difference under the reference illuminant is to be measured in colour coordinates L*, a* and b* (see EN 13523-3:2001).
Excluded from this method are organic coatings producing fluorescence and/or which are multicoloured, pearlescent or metallic.
*
*
*