Skip to main content
Back

Sorry - this product is no longer available

EVS-EN 15502-2-1:2012

Gas-fired central heating boilers - Part 2-1: Specific standard for type C appliances and type B2, B3 and B5 appliances of a nominal heat input not exceeding 1 000 kW

General information

Withdrawn from 03.01.2017
Base Documents
EN 15502-2-1:2012
Directives or regulations
None

Standard history

Status
Date
Type
Name
03.01.2017
Main + amendment
EVS-EN 15502-2-1:2012+A1:2016
05.12.2012
Main
EVS-EN 15502-2-1:2012
05.03.2009
Corrigendum
EVS-EN 483:2000/A2:2002/AC:2006
Main
EVS-EN 483:2000
Amendment
EVS-EN 483:2000/A2:2002
Amendment
EVS-EN 483:2000/A4:2007
Main
EVS-EN 15420:2010
This European Standard specifies, the requirements and test methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”. Where the word boiler is used, it must be read as the boiler including its connecting ducts, ducts and terminals, if any. This European Standard covers gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in CEN/TR 1749:2009: a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1000 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which may or may not give rise to condensation under certain circumstances; f) which are declared in the installation instructions to be either a “condensing” boiler or a "low temperature boiler" or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”; g) which are intended to be installed either indoors or outdoors in a partially protected place; h) which may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit; i) which are designed for either sealed water systems or for open water systems; j) which are either modular boilers, or non- modular boilers.

Required fields are indicated with *

*
*
*
PDF
27.02 € incl tax
Paper
27.02 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 15502-2-2:2014

Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances
Newest version Valid from 03.09.2014
Main

EVS-EN 89:2000

Gas-fired storage water heaters for sanitary use
Withdrawn from 08.06.2015
Amendment

EVS-EN 89:2000/A4:2006

Gas-fired storage water heaters for the production of domestic hot water
Withdrawn from 08.06.2015
Main

EVS-EN 13203-1:2006

Gas-fired domestic appliances producing hot water - Appliances not exceding 70 kW heat input and 300 l water storage capacity - Part 1: Assessment of performance of hot water deliveries
Withdrawn from 06.10.2015