Back

EVS-EN 1707:1999

Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Lock fittings

General information
Withdrawn from 16.06.2017
Base Documents
EN 1707:1996
Directives or regulations
93/42/EEC Medical devices (MDD)

Although the standard’s status is withdrawn, it still has the presumption of conformity in the meaning of regulation 93/42/EEC and conformance with the regulation ’s requirements can be guaranteed by using the withdrawn version of the standard. The presumption of conformity is valid until a corresponding amendment is published in the Official Journal of the European Union.
 
To view the latest lists of harmonised standards published in the Official Journal of the European Union, visit: 
http://ec.europa.eu/growth/single-market/european-standards/harmonised-standards/

Standard history

Status
Date
Type
Name
16.06.2017
Main
01.01.2000
Main
This European Standard specifies requirements for conical lock fittings with a 6 % (Luer) taper for use with hypodermic syringes and needles and with certain other apparatus for medical use e.g. transfusion equipment.  The requirements apply to fittings made of rigid and of semi-rigid materials and include test methods, but exclude provision for more flexible or elastomeric materials.  NOTE 1. It is not practicable to define the characteristics of rigid or semi-rigid materials with precision, but glass and metal may be considered as typical rigid materials. In contrast many plastics materials may be regarded as semi-rigid.  NOTE 2. The Luer lock fitting was designed for use at pressures of the order of 300 kPa or lower. Its use in other applications may require consideration to establish its suitability.
*
*
*
PDF
13.42 € incl tax
Paper
13.42 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 868-5:2009

Packaging for terminally sterilized medical devices - Part 5: Sealable pouches and reels of porous materials and plastic film construction - Requirements and test methods
Withdrawn from 03.01.2019
Main

EVS-EN ISO 10993-3:2014

Biological evaluation of medical devices - Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity (ISO 10993-3:2014)
Newest version Valid from 07.11.2014
Main

EVS-EN ISO 11135:2014

Sterilization of health-care products - Ethylene oxide - Requirements for the development, validation and routine control of a sterilization process for medical devices (ISO 11135:2014)
Newest version Valid from 04.08.2014
Main

EVS-EN ISO 10993-12:2012

Biological evaluation of medical devices - Part 12: Sample preparation and reference materials (ISO 10993-12:2012)
Withdrawn from 01.07.2021