Skip to main content
Back

Sorry - this product is no longer available

prEN 50576

Electric cables - Extended application of test results for reaction to fire

General information

Draft
Base Documents
prEN 50576
Directives or regulations
None

Standard history

Status
Date
Type
Name
Main
prEN 50576
03.01.2017
Main
This EN gives the procedure and rules for extended application of results of tests carried out according to the test methods described in EN 50399, EN 60332-1-2 and EN 61034-2. The EXAP rules described apply to EN 50399 test results used for classification in classes B2ca, Cca and Dca, additional smoke production classes s1, s2 and s3 and flaming droplets/particles, to EN 60332-1-2 test results used for classification in classes B2ca, Cca, Dca and Eca and to EN 61034 2 test results used for classification in classes s1a and s1b. No EXAP procedure and rules have been developed in respect of the results of tests carried out according to the test method described in EN 60754-2. As the parameters (pH and conductivity) for each cable in a family are determined based upon calculation using material test results, this is considered as a matter of direct application. Material test results taken from any one sample of finished cable from a family are sufficient to calculate the parameters for each cable in the family. Cables of diameter 5,0 mm and less should be tested as bundles according to EN 50399. Bundled cables are not included in the EXAP rules applying to EN 50399 test results. The rules apply to circular and non-circular cables provided that they fall within the scope of the relevant test method. A specific EXAP rule has been developed for the most common generic power cable families, optical fibre cables and copper communication cables (CCC). A general EXAP rule has been developed for any power cable families. The general EXAP rule is not applicable to communication or optical fibre cables. NOTE 1 Multicore power cables are sometimes referred to as control cables with a rated voltage but for the purposes of this standard are considered as power cables. For multipair, multitriple and multiquad control cables either the general EXAP rule for power cables or the specific EXAP rule for copper communication cables can be applied. The general EXAP rule may be applied in the case of hybrid cables provided that the conditions of 6.1 are fulfilled. The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range of cable constructions (product family). An EXAP is only possible when cables belong to a defined family as defined in this standard.

Required fields are indicated with *

*
*
*
PDF
8.24 € incl tax
Paper
8.24 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 50565-1:2014

Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U₀/U) - Part 1: General guidance
Newest version Valid from 06.05.2014
Main

EVS-EN 50565-2:2014

Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) -- Part 2: Specific guidance related to EN 50525 cable types
Newest version Valid from 06.05.2014
Main

EVS-EN IEC 63000:2018

Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances
Newest version Valid from 19.12.2018
Main

EVS-EN 50288-7:2005

Multi-element metallic cables used in analogue and digital communication and control Part 7: Sectional specification for instrumentation and control cables
Newest version Valid from 04.11.2005