Tagasi

Vabandust – see toode pole enam saadaval

EVS-EN 12102:2013

Elektrikompressoritega õhu konditsioneerid, vedelikjahutusseadmed, soojuspumbad ja õhukuivatid ruumide kütteks ja jahutuseks. Õhumüra mõõtmine. Helivõimsuse taseme määramine

Üldinfo
Kehtetu alates 18.12.2017
Alusdokumendid
EN 12102:2013
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
18.12.2017
Põhitekst
09.09.2013
Põhitekst
EVS-EN 12102:2013
Põhitekst
EVS-EN 12102:2008
This European Standard establishes requirements for determining, in accordance with a standardized procedure, the sound power level emitted into the surrounding air by air conditioners, heat pumps, liquid chilling packages with electrically driven compressors when used for space heating and/or cooling, including water cooled multisplit systems, as described in FprEN 14511:2012 and dehumidifiers as described in EN 810:1997. This standard also covers the measurement of the sound power level of evaporatively-cooled condenser air conditioners, as defined in EN 15218:2012. However, the measurement shall be done without external water feeding and these units will thus be considered as the other air conditioners covered by EN 14511:2012. It is emphasised that this measurement standard only refers to airborne noise. This European Standard offers ways to determine the sound power level of units. Some of them are specifically adapted to provide results with low uncertainties, by using laboratory class acoustic methods and highly controlled working conditions. Those measurements are suitable for certification, labelling and marking purposes. In some cases, the target and/or the environment of the measurements do not allow such precision-class methods. This European Standard also offers ways to assess sound power levels with acceptable accuracy even though acoustic methods and/or working conditions are not laboratory-type, e.g. in situ or quality control measurements. This European Standard gives two classes of measurements and results, according to the test environment: Class A measurements correspond to controlled working conditions (standard or application rating conditions). It is defined by the respect to the tolerances of Table 2 and shall be used for the conformity to requirements of the Commission Regulation (EC) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for air conditioners Class B measurements correspond to the case where the range defined by the tolerances of Table 2 cannot be fulfilled. In both classes, precision or engineering class acoustic methods should be applied. The choice of the acoustic measurement method is done in accordance with EN ISO 3740 and EN ISO 9614 depending on the type of surrounding acoustic fields (diffuse or free field, enclosed or open space), and the available instrumentation. Whatever the current working conditions, the reference of acoustic standard shall be reported, with explicit mention of its accuracy class.
*
*
*
PDF
15,26 € koos KM-ga
Paber
15,26 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 13203-1:2006

Gas-fired domestic appliances producing hot water - Appliances not exceding 70 kW heat input and 300 l water storage capacity - Part 1: Assessment of performance of hot water deliveries
Kehtetu alates 06.10.2015
Põhitekst

EVS-EN 13203-3:2010

Solar supported gas-fired domestic appliances producing hot water - Appliances not exceeding 70 kW heat input and 500 liters water storage capacity - Part 3: Assessment of energy consumption
Kehtetu alates 01.09.2022
Põhitekst

EVS-EN 15502-2-2:2014

Gaas-keskküttekatlad. Osa 2-2: Eristandard B1 tüüpi kateldele
Uusim versioon Kehtiv alates 03.09.2014
Põhitekst

EVS-EN 15036-1:2006

Heating boilers - Test regulations for airborne noise emissions from heat generators - Part 1: Airborne noise emissions from heat generators