prEN 50576

Electric cables - Extended application of test results for reaction to fire

Üldinfo
Kavand
Alusdokumendid
prEN 50576
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
Põhitekst
prEN 50576
03.01.2017
Põhitekst
This EN gives the procedure and rules for extended application of results of tests carried out according to the test methods described in EN 50399, EN 60332-1-2 and EN 61034-2. The EXAP rules described apply to EN 50399 test results used for classification in classes B2ca, Cca and Dca, additional smoke production classes s1, s2 and s3 and flaming droplets/particles, to EN 60332-1-2 test results used for classification in classes B2ca, Cca, Dca and Eca and to EN 61034 2 test results used for classification in classes s1a and s1b. No EXAP procedure and rules have been developed in respect of the results of tests carried out according to the test method described in EN 60754-2. As the parameters (pH and conductivity) for each cable in a family are determined based upon calculation using material test results, this is considered as a matter of direct application. Material test results taken from any one sample of finished cable from a family are sufficient to calculate the parameters for each cable in the family. Cables of diameter 5,0 mm and less should be tested as bundles according to EN 50399. Bundled cables are not included in the EXAP rules applying to EN 50399 test results. The rules apply to circular and non-circular cables provided that they fall within the scope of the relevant test method. A specific EXAP rule has been developed for the most common generic power cable families, optical fibre cables and copper communication cables (CCC). A general EXAP rule has been developed for any power cable families. The general EXAP rule is not applicable to communication or optical fibre cables. NOTE 1 Multicore power cables are sometimes referred to as control cables with a rated voltage but for the purposes of this standard are considered as power cables. For multipair, multitriple and multiquad control cables either the general EXAP rule for power cables or the specific EXAP rule for copper communication cables can be applied. The general EXAP rule may be applied in the case of hybrid cables provided that the conditions of 6.1 are fulfilled. The use of the specific EXAP rule gives benefit in the lower number of cables to be tested for a range of cable constructions (product family). An EXAP is only possible when cables belong to a defined family as defined in this standard.
*
*
*
PDF
8,24 € koos KM-ga
Paber
8,24 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 50565-1:2014

Juhtmed ja kaablid. Juhis tugevvoolujuhtmete ja -kaablite kasutamiseks nimipingel kuni 450/750 V (U₀/U). Osa 1: Üldjuhis
Uusim versioon Kehtiv alates 06.05.2014
Põhitekst

EVS-EN 50565-2:2014

Juhtmed ja kaablid. Juhis tugevvoolujuhtmete ja -kaablite nimipingega kuni 450/750 V (U0/U) kasutamiseks. Osa 2: Erijuhis standardis EN 50525 käsitletud juhtme- ja kaabliliikidele
Uusim versioon Kehtiv alates 06.05.2014
Põhitekst

EVS-EN IEC 63000:2018

Tehniline dokumentatsioon elektriliste ja elektrooniliste toodete hindamiseks ohtlike ainete piirangu seisukohast
Uusim versioon Kehtiv alates 19.12.2018
Põhitekst

EVS-EN 50288-7:2005

Analoog- ja digitaalkommunikatsioonis ja -juhtimises kasutatavad mitmeelemendilised metallkaablid. Osa 7: Seadistus- ja juhtimiskaablite liigitus
Uusim versioon Kehtiv alates 04.11.2005