Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly)

General information
Valid from 04.03.2014
Base Documents
EN 1364-3:2014
Directives or regulations
None

Standard history

Status
Date
Type
Name
04.03.2014
Main
08.10.2007
Main
This European Standard specifies a method for determining the fire resistance of curtain walling full configuration.
This European Standard is used in conjunction with EN 1363 1.
NOTE  Annex B gives further information on the test method.
The test method is applicable to curtain walling type B (for definition see 3.4). The test is not appropriate for testing curtain walling type A (for definition see 3.3).
The fire resistance of curtain walling may be determined under internal or external exposure conditions. In the latter case the external fire exposure curve given in EN 1363 2 may be used, subject to deviating national regulations.
Tests on individual parts of a curtain walling (e.g. perimeter seal, infill panel or fixing of the framing system (anchoring) used to attach the curtain walling to the floor element) or systems with fire resistance requirements only to the spandrel area may be performed using EN 1364 4. For vertical linear gap seals, this part of the standard applies.
This European Standard does not cover double skin façades, over-cladding systems and ventilated façade systems on external walls. It does not deal with the reaction to fire behaviour of curtain walling.
This standard is intended to be read in conjunction with EN 1363 1 and EN 1363 2.
*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 1364-4:2014

Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
Newest version Valid from 04.03.2014
Main

EVS-EN 15254-6:2014

Extended application of results from fire resistance tests - Non-loadbearing walls - Part 6: Curtain walling
Newest version Valid from 04.03.2014
Main

EVS-EN 1364-1:2015

Fire resistance tests for non-loadbearing elements - Part 1: Walls
Newest version Valid from 05.08.2015
Main

EVS-EN 1634-1:2014

Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows
Withdrawn from 01.02.2018