EVS-EN 15502-2-1:2012

Gaasküttega keskküttekatlad. Osa 2-1: Erinõuded C tüüpi kateldele ja B2, B3 ning B5 tüüpi kateldele nimisoojuskoormusega mitte üle 1 000 kW

Üldinfo
Kehtetu alates 03.01.2017
Alusdokumendid
EN 15502-2-1:2012
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
03.01.2017
Põhitekst + muudatus
EVS-EN 15502-2-1:2012+A1:2016
05.12.2012
Põhitekst
EVS-EN 15502-2-1:2012
05.03.2009
Parandus
EVS-EN 483:2000/A2:2002/AC:2006
Põhitekst
EVS-EN 483:2000
Muudatus
EVS-EN 483:2000/A2:2002
Muudatus
EVS-EN 483:2000/A4:2007
Põhitekst
EVS-EN 15420:2010
This European Standard specifies, the requirements and test methods concerning, in particular, the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners or fully premixed burners, and are hereafter referred to as “boilers”. Where the word boiler is used, it must be read as the boiler including its connecting ducts, ducts and terminals, if any. This European Standard covers gas-fired central heating boilers from the types C1 up to C9 and the types B2, B3 and B5, according to the classification in CEN/TR 1749:2009: a) that have a nominal heat input (on the basis of net calorific value) not exceeding 1000 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) which may or may not give rise to condensation under certain circumstances; f) which are declared in the installation instructions to be either a “condensing” boiler or a "low temperature boiler" or a “standard boiler”. If no declaration is given the boiler is to be considered a “standard boiler”; g) which are intended to be installed either indoors or outdoors in a partially protected place; h) which may include the facility to produce hot water, either by the instantaneous or storage principle, the whole being marketed as a single unit; i) which are designed for either sealed water systems or for open water systems; j) which are either modular boilers, or non- modular boilers.
*
*
*
PDF
27,02 € koos KM-ga
Paber
27,02 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 15502-2-2:2014

Gaas-keskküttekatlad. Osa 2-2: Eristandard B1 tüüpi kateldele
Uusim versioon Kehtiv alates 03.09.2014
Põhitekst

EVS-EN 89:2000

Gaasiküttega paagiveesoojendid sanitaarkasutusele
Kehtetu alates 08.06.2015
Muudatus

EVS-EN 89:2000/A4:2006

Gaasiküttega paagiveesoojendid sanitaarkasutusele
Kehtetu alates 08.06.2015
Põhitekst

EVS-EN 13203-1:2006

Gas-fired domestic appliances producing hot water - Appliances not exceding 70 kW heat input and 300 l water storage capacity - Part 1: Assessment of performance of hot water deliveries
Kehtetu alates 06.10.2015