prEN 81-58

Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test

General information

Draft
Base Documents
prEN 81-58
Directives or regulations
None
You can view draft standards in the Commenting portal🡭.

Standard history

Status
Date
Type
Name
Main
01.06.2022
Main
This document defines the fire resistance test and requirements for landing doors which are intended to provide a barrier to the spread of fire from the landing side and via the lift well in buildings for a period of time classified in this document. The fire resistance requirements are expressed in terms of integrity (E), insulation (EI) and radiation (EW).
It is applicable to landing doors installed in the lift well openings at landings and used as means of access to lift car.
It also specifies the method of testing and classification of fire resistance of landing doors. The test method is only valid for furnaces where the door is mounted in a vertical position. The test method specifies the measurement of integrity and if required the measurement of radiation and thermal insulation.
This document refers to CO2 as means of tracing the propagation of fire. The document does not cover hazards due to emission of gases.
This document is not applicable to landing doors which are installed before the date of its publication.