EVS-EN 16905-2:2026

Gas-fired endothermic engine driven heat pumps - Part 2: Safety

General information

Valid from 01.10.2026
Base Documents
EN 16905-2:2026
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.10.2026
Main
03.02.2020
Main
This part of EN 16905 specifies the safety requirements, the safety test conditions and the safety test methods of gas-fired endothermic engine driven heat pumps for heating and/or cooling mode including the engine heat recovery, to be used outdoors.
This document specifies minimum operating requirements which ensure that the products are fit for the use designated by the manufacturer when used for space heating and/or cooling.
This document is used in conjunction with:
a)  the terms and conditions, EN 6905-1:2023;
b)  the test conditions, EN 16905-3:2024;
c)  the test methods, EN 16905-4:2026;
d)  the calculation of seasonal performances in heating and cooling mode, EN 16905-5:2022;
e)  the heat pump, EN 14511-4:2022, EN 378-1:2016+A1:2020, EN 378-2:2016, EN 378-3:2016+A1:2020, EN 378-4:2016+A1:2019 and EN 14825:2022;
f)  electrical safety, EN 60335-1:2012, EN 60335-2-102:2016, EN 60335-2-40:2003 and EN 60204- 1:2018.
This document only applies to GEHP appliances with a maximum heat input (based on net calorific value) not exceeding 70 kW at standard rating conditions.
This document only applies to GEHP appliances under categories I2H, I2E, I2Er, I2R, I2E(S)B, I2L, I2LL, I2ELL, I2E(R)B, I2ESi, I2E(R), I3P, I3B, I3B/P, II2H3+, II2Er3+, II2H3B/P, II2L3B/P, II2E3B/P, II2ELL3B/P, II2L3P, II2H3P, II2E3P and II2Er3P according to EN 437:2021.
This document only applies to GEHP appliances:
a)  that have gas fired endothermic engines under the control of fully automatic control systems;
b)  that have closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated;
c)  where the temperature of the heat transfer fluid of the heating system (heating water circuit) does not exceed 105 °C during normal operation;
d)  where the maximum operating pressure in the:
1)  heating water circuit (if installed) does not exceed 6 bar;
2)  domestic hot water circuit (if installed) does not exceed 10 bar.
This document is applicable to GEHP appliances only when used for space heating or space cooling or for refrigeration, with or without heat recovery.
NOTE  This document provides requirements for GEHP appliances with known constructions. For GEHP appliances with any alternative constructions, which are not fully be covered by this standard, the risk associated with this alternative construction needs to be assessed.