EVS-EN 416:2019

Gas-fired overhead radiant tube heaters and radiant tube heater systems for non-domestic use - Safety and energy efficiency

General information
Valid from 01.11.2019
Base Documents
EN 416:2019
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.11.2019
Main
08.10.2009
Main
08.10.2009
Main
08.10.2009
Main
08.10.2009
Main
08.08.2006
Main
This European Standard specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant tube heaters incorporating a single burner and multiple burner systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system.
For radiant tube heaters incorporating a single burner, this standard is applicable to Type A2, A3, B12, B13, B22, B23, B42, B43, B52, B53, C12, C13, C32, C33, C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means located upstream of the draught diverter, if provided.
For radiant tube heater systems incorporating multiple tube heater segments, this standard is applicable to Type B52, B52x, B53 and B53x systems intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means.
This standard also includes appliances incorporating a secondary heat exchanger in the flue system.
This standard is not applicable to:
a)  appliances designed for use in domestic dwelling;
b)  outdoor appliances;
c)  appliances where the heat input of any individual burner unit is in excess of 120 kW (based on the net calorific value of the appropriate reference test gas);
d)  appliances having combustion products evacuation ducts that are non-metallic in the flue system - except ducts downstream of a possible additional condensing exhaust gas heat exchanger.
In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to:
e)  appliances and systems that are designed for continuous condensation within the flue system under normal operating conditions - except downstream a possible additional exhaust gas heat exchanger.
This standard is applicable to systems which are intended to be type tested.
*
*
*
PDF
46.36 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 419:2019

Gas-fired overhead luminous radiant heaters for non-domestic use - Safety and energy efficiency
Newest version Valid from 01.11.2019
Main

EVS-EN 17175:2019

Gas-fired overhead radiant strip heaters and multi-burner continuous radiant tube heater systems for non-domestic use - Safety and energy efficiency (Corrected version 2019-12)
Newest version Valid from 01.11.2019
Main

EVS-EN 17082:2019

Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW
Newest version Valid from 01.11.2019