Skip to main content
Back

EVS-EN 50306-2:2020

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables

General information

Valid from 02.04.2020
Base Documents
EN 50306-2:2020
Directives or regulations
None

Standard history

Status
Date
Type
Name
02.04.2020
Main
01.02.2003
Main
This document specifies requirements for, and constructions and dimensions of, single core cables, rated voltage U0 / U = 300 /300 V, of the following type:
Unscreened (0,5 mm2 to 2,5 mm2 single core)
These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 105 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C/20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545-1 and EN 45545-2.
EN 50306-2:2020 is expected to be used in conjunction with EN 50306-1:2020, General requirements.

Required fields are indicated with *

*
*
*
PDF
15.86 € incl tax
Paper
15.86 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 50306-1:2020

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
Newest version Valid from 02.04.2020
Main

EVS-EN 50306-3:2020

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables screened and thin wall sheathed
Newest version Valid from 02.04.2020
Main

EVS-EN 50306-4:2020

Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair screened or not screened sheathed cables
Newest version Valid from 02.04.2020
Main

EVS-EN 50264-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
Newest version Valid from 05.09.2008