Skip to main content
Back

EVS-EN 50525-3-41:2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke

General information

Valid from 02.06.2011
Base Documents
EN 50525-3-41:2011
Directives or regulations
2014/35/EU Low voltage (LVD)

Standard history

Status
Date
Type
Name
EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in accordance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 °C. NOTE 3 HD 516 contains extensive guidance on the safe use of cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements.

Required fields are indicated with *

*
*
*
PDF
12.20 € incl tax
Paper
12.20 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 50525-1:2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
Valid from 02.06.2011
Main

EVS-EN 50525-2-11:2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
Newest version Valid from 02.06.2011
Main

EVS-EN 50525-2-21:2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
Newest version Valid from 02.06.2011
Main

EVS-EN 50525-2-31:2011

Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
Newest version Valid from 02.06.2011