EVS-EN 60601-1-10:2008+A1+A2:2021

Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers (IEC 60601-1-10:2007 + IEC 60601-1-10:2007/A1:2013 + IEC 60601-1-10:2007/A2:2020)

General information
Valid from 17.08.2021
Base Documents
IEC 60601-1-10:2007; EN 60601-1-10:2008; IEC 60601-1-10:2007/A1:2013; EN 60601-1-10:2008/A1:2015; IEC 60601-1-10:2007/A2:2020; EN 60601-1-10:2008/A2:2021
Directives or regulations
None
Standard history
Status
Date
Type
Name
17.08.2021
Main + amendment
03.08.2021
Amendment
08.06.2015
Amendment
09.06.2008
Main
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS. This collateral standard specifies requirements for the development (analysis, design, VERIFICATION and VALIDATION) of a PHYSIOLOGIC CLOSED-LOOP CONTROLLER (PCLC) as part of a PHYSIOLOGIC CLOSED-LOOP CONTROL SYSTEM (PCLCS) to control at least one PATIENT VARIABLE (i.e. a PHYSIOLOGIC VARIABLE) in ME EQUIPMENT and ME SYSTEMS. EXAMPLE A PATIENT VARIABLE can be a measure of body chemistry (e.g. electrolytes or blood glucose value), a physical property (e.g. body temperature, electrophysiologic characteristic, hemodynamic quantity), or a pharmaceutical concentration. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard does not specify: − additional mechanical requirements; or − additional electrical requirements. This collateral standard applies to a closed-loop controller (see Figure 1) that sets the CONTROLLER OUTPUT VARIABLE in order to adjust (i.e., change or maintain) the measured PHYSIOLOGIC VARIABLE by relating it to the REFERENCE VARIABLE. A closed-loop controller that maintains a physical or chemical VARIABLE, using feedback that is not measured from a PATIENT, is outside the scope of this standard.
*
*
*
PDF
21.60 € incl tax
Paper
21.60 € incl tax
Browse a standard: 2.40 € incl tax
Standard monitoring
Customers who bought this item also bought
Main + amendment

EVS-EN 60601-1-8:2007+A1+A11+A2:2021

Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems (IEC 60601-1-8:2006 + IEC 60601-1-8:2006/A1:2012 + IEC 60601-1-8:2006/A2:2020)
Newest version Valid from 17.08.2021
Main + amendment

EVS-EN 60601-1:2006+A1+A12+A2:2021

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005, modified + A1:2013 + A12:2014 + IEC 60601-1:2005/A2:2020)
Newest version Valid from 01.11.2021
Main + amendment

EVS-EN 62133-2:2017+A1:2021

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems (IEC 62133-2:2017 + IEC 62133-2:2017/AMD1:2021)
Newest version Valid from 01.10.2021
Main

EVS-EN ISO 17664-1:2021

Processing of health care products - Information to be provided by the medical device manufacturer for the processing of medical devices - Part 1: Critical and semi-critical medical devices (ISO 17664-1:2021)
Newest version Valid from 16.09.2021