Skip to main content
Back

EVS-EN 60601-2-44:2009+A11+A1+A2

Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

General information

Valid from 02.08.2017
Base Documents
EN 60601-2-44:2009; IEC 60601-2-44:2009; EN 60601-2-44:2009/A11:2011; EN 60601-2-44:2009/A1:2012; IEC 60601-2-44:2009/A1:2012; EN 60601-2-44:2009/A2:2016; IEC 60601-2-44:2009/A2:2016
Directives or regulations
None

Standard history

Status
Date
Type
Name
02.08.2017
Main + amendment
05.07.2016
Amendment
05.12.2012
Amendment
02.11.2011
Amendment
07.08.2009
Main
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of CT SCANNERS, hereafter also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
NOTE 1 See also 4.2 of the general standard.
The scope of this document is limited to CT SCANNERS intended to be used for both head and body characterised by an ENCLOSURE of the X-ray source(s) and imaging detector(s) in a common protective cover in the shape of a toroid. It includes safety requirements for the XRAY GENERATORS used in CT SCANNERS, including those where HIGH-VOLTAGE GENERATORS are
integrated with an X-RAY TUBE ASSEMBLY.
NOTE 2 Requirements for X-RAY GENERATORS and for ASSOCIATED EQUIPMENT, which were previously specified in IEC 60601-2-7 and IEC 60601-2-32, have been included in either IEC 60601-1:2005 (Ed3) or this edition of IEC 60601-2-44. Therefore IEC 60601-2-7 and IEC 60601-2-32 are not part of the 3rd edition scheme for COMPUTED TOMOGRAPHY.
The scope of this International Standard excludes RADIOTHERAPY SIMULATORS and systems
where the image is created by a source other than an X-RAY TUBE.

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 60601-2-54:2009+A1+A2:2019

Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy (IEC 60601-2-54:2009 + IEC 60601-2-54:2009/A1:2015 + IEC 60601-2-54:2009/A2:2018)
Newest version Valid from 15.08.2019
Main

EVS-EN IEC 60601-2-28:2019

Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
Newest version Valid from 15.10.2019
Main + amendment

EVS-EN 60601-2-63:2015+A1+A2:2021

Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment (IEC 60601-2-63:2012 + IEC 60601-2-63:2012/A1:2017 + IEC 60601-2-63:2012/A2:2021)
Newest version Valid from 01.07.2021
Main + amendment

EVS-EN 60601-2-43:2010+A1+A2:2020

Medical electrical equipment - Part 2-43: Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures (IEC 60601-2-43:2010 + IEC 60601-2-43:2010/A1:2017 + IEC 60601-2-43:2010/A2:2019)
Withdrawn from 03.04.2023