Back

EVS-EN 60601-2-5:2015

Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment

General information
Valid from 04.11.2015
Base Documents
EN 60601-2-5:2015; IEC 60601-2-5:2009
Directives or regulations
None

Standard history

Status
Date
Type
Name
04.11.2015
Main
01.01.2003
Main
IEC 60601-2-5:2009 applies to the basic safety and essential performance of ultrasonic physiotherapy equipment employing a single plane unfocused circular transducer per treatment head, producing static beams perpendicular to the face of the treatment head. This standard can also be applied to ultrasonic physiotherapy equipment used for compensation or alleviation of disease, injury or disability. This third edition cancels and replaces the second edition published in 2000. This edition constitutes a technical revision. The numbering was revised to agree with IEC 60601-1:2005 (third edition). Beyond this, essential performance characteristics are defined in 201.4.3.101, guidance on maintenance is added in 201.7.9.2.1, a new requirement regarding dielectric withstand was added in 201.8.8.3. The clause on transducer surface temperature rise, 201.11, has been modified to allow for simulated use conditions. Measurements of ultrasound-related parameters are now referenced to IEC 61689:2007 (second edition). The most important change in the ultrasound-related parameters is the definition of effective radiating area, 201.3.207. This change will also affect the value of the effective intensity and its uncertainty.
*
*
*
PDF
24.40 € incl tax
Paper
24.40 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN 60601-1-2:2015+A1:2021

Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests (IEC 60601-1-2:2014 + IEC 60601-1-2:2014/A1:2020)
Newest version Valid from 01.04.2021
Main + amendment

EVS-EN 60601-1:2006+A1+A12+A2:2021

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005, modified + A1:2013 + A12:2014 + IEC 60601-1:2005/A2:2020)
Newest version Valid from 01.11.2021
Main

EVS-EN 60601-2-37:2008

Medical electrical equipment -- Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
Newest version Valid from 07.03.2008
Amendment

EVS-EN 60601-2-37:2008/A11:2011

Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
Newest version Valid from 02.11.2011