Skip to main content
Back

EVS-EN IEC 62990-1:2022+A11:2022

Workplace atmospheres - Part 1: Gas detectors - Performance requirements of detectors for toxic gases (IEC 62990-1:2019 + COR1:2019)

General information

Valid from 15.06.2023
Base Documents
IEC 62990-1:2019; IEC 62990-1:2019/COR1:2019; EN IEC 62990-1:2022; EN IEC 62990-1:2022/A11:2022
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.06.2023
Main + amendment
01.11.2022
Main
01.11.2022
Amendment
This part of IEC 62990 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present.
This document applies to two types of equipment:
•  Type HM (Health Monitoring) ‘occupational exposure’ equipment:
For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1.
•  Type SM (Safety Monitoring) ‘general gas detection’ equipment:
For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment.
In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM.
For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour.
This document is not applicable to equipment:
–  with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
–  used for the measurement of gases and vapours related to the risk of explosion;
–  used for the measurement of oxygen;
–  used only in laboratories for analysis or measurement;
–  used only for process measurement purposes;
–  used in the domestic environment;
–  used in environmental air pollution monitoring;
–  used for open-path (line of sight) area gas measurement;
–  used for ventilation control in car parks or tunnels.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 50270:2015

Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
Newest version Valid from 04.02.2015
Main

EVS-EN 50271:2018

Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies
Newest version Valid from 04.07.2018
Main

EVS-EN 50104:2019

Electrical equipment for the detection and measurement of oxygen - Performance requirements and test methods
Newest version Valid from 15.11.2019
Main

EVS-EN 50402:2017

Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems
Newest version Valid from 04.04.2017