Skip to main content
Back

EVS-EN ISO 16266-2:2021

Water quality - Detection and enumeration of Pseudomonas aeruginosa - Part 2: Most probable number method (ISO 16266-2:2018)

General information

Valid from 01.12.2021
Base Documents
ISO 16266-2:2018; EN ISO 16266-2:2021
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.12.2021
Main
This document specifies a method for the enumeration of Pseudomonas aeruginosa in water. The method is based on the growth of target organisms in a liquid medium and calculation of the most probable number (MPN) of organisms by reference to MPN tables.
This document is applicable to a range of types of water. For example, hospital waters, drinking water and non‐carbonated bottled waters intended for human consumption, groundwater, swimming pool and spa pool waters including those containing high background counts of heterotrophic bacteria.
This document does not apply to carbonated bottled waters, flavoured bottle waters, cooling tower waters or marine waters, for which the method has not been validated. These waters are, therefore, outside the scope of this document. Laboratories can employ the method presented in this document for these matrices by undertaking appropriate validation of performance of this method prior to use.
The test is based on a bacterial enzyme detection technology that signals the presence of P. aeruginosa through the hydrolysis of a 7‐amino‐4‐methylcoumarin aminopeptidase substrate present in a special reagent. P. aeruginosa cells rapidly grow and reproduce using the rich supply of amino acids, vitamins
and other nutrients present in the reagent. Actively growing strains of P. aeruginosa have an enzyme that cleaves the 7‐amido‐coumarin aminopeptidase substrate releasing a product which fluoresces under ultraviolet (UV) light. The test described in this document provides a confirmed result within 24 h with no requirement for further confirmation of positive wells.

Required fields are indicated with *

*
*
*
PDF
39.04 € incl tax
Paper
39.04 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 7899-2:2002

Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
Newest version Valid from 01.06.2002
Main + amendment

EVS-EN ISO 9308-1:2014+A1:2017

Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora (ISO 9308-1:2014 + ISO 9308-1:2014/Amd 1:2016)
Newest version Valid from 03.02.2017
Main + amendment

EVS-EN ISO 21149:2017+A1:2022

Cosmetics - Microbiology - Enumeration and detection of aerobic mesophilic bacteria (ISO 21149:2017 + ISO 21149:2017/Amd 1:2022)
Newest version Valid from 01.11.2022
Main + amendment

EVS-EN ISO 21150:2015+A1:2022

Cosmetics - Microbiology - Detection of Escherichia coli (ISO 21150:2015 + ISO 21150:2015/Amd 1:2022)
Newest version Valid from 01.11.2022