Back

EVS-HD 60364-7-712:2016

Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems

General information
Valid from 03.05.2016
Base Documents
HD 60364-7-712:2016
Directives or regulations
None
Standard history
Status
Date
Type
Name
03.05.2016
Main
07.09.2005
Main
This section applies to the electrical installation of PV generator intended to supply all or part of an installation and feeding of electricity into the public grid or local distribution. In this section, the electrical equipment of a PV generator, like any other item of electrical equipment, is dealt with only so far as its selection and application in the installation is concerned. The electrical installation of a PV generator starts from a PV module or a set of PV modules connected in series with their cables, provided by the PV module manufacturer, up to the user installation or the utility supply point. Requirements of this document apply to – PV generators for supply to an installation which is not connected to a system for distribution of electricity to the public, – PV generators for supply to an installation in parallel with a system for distribution of electricity to the public, – PV generators for supply to an installation as an alternative to a system for distribution of electricity to the public, – appropriate combination of the above. Requirements for PV generators with batteries or other energy storage methods are under consideration.
*
*
*
PDF
15.86 € incl tax
Paper
15.86 € incl tax
Price: 2.40 € incl tax
Standard monitoring
Customers who bought this item also bought
Main

EVS-HD 60364-7-722:2016

Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
Withdrawn from 01.08.2019
Main + corrigendum

EVS-EN 61140:2016

Protection against electric shock - Common aspects for installation and equipment
Newest version Valid from 01.06.2016
Main

EVS-HD 60364-5-534:2016

Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Devices for protection against overvoltages
Newest version Valid from 02.03.2016
Main

EVS-HD 60364-4-443:2016

Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against overvoltages of atmospheric origin or due to switching
Newest version Valid from 02.03.2016