Skip to main content
Back

Sorry - this product is no longer available

FprEN IEC 61010-2-091:2018/prAA

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-091: Particular requirements for cabinet X-ray systems

General information

Draft
Base Documents
FprEN IEC 61010-2-091:2018/prAA
Directives or regulations
None

Standard history

Status
Date
Type
Name
Amendment
FprEN IEC 61010-2-091:2018/prAA
Main
prEN 61010-2-091:2017
1 Scope and object This clause of Part 1 is applicable, except as follows: 1.1 Scope 1.1.1 Equipment included in scope Deletion: Delete the first paragraph. Replacement: Replace the second paragraph (above items a) to c)) with the following new text: This part of IEC 61010 specifies particular safety requirements for cabinet X-ray systems, which fall under any of categories a), b) or c) below. Addition: Add the two following new paragraphs at the end of the subclause: Equipment covered by this document can be both PROTECTED EQUIPMENT or PARTIALLY PROTECTED EQUIPMENT, with X-ray generator voltage up to 500 kV. A cabinet X-ray system is a system that contains an X-ray tube installed in a cabinet, which, independently of existing architectural structures except the floor on which it may be placed, is intended to contain at least that portion of a material being irradiated, provide radiation attenuation and prevent operator access to the radiation beam, during generation of X-radiation. These cabinet X-ray systems are used in industrial, commercial, and public environments, for example, to inspect materials, to analyse materials, and to screen baggage. 1.1.2 Equipment excluded from scope Addition: Add the following new items to the list: aa) Equipment intended to apply X-radiation to humans or animals; bb) Equipment incorporating an X-ray tube but not incorporating complete shielding against X-radiation HAZARDS, such as: – equipment intended to be used within a shielded room which excludes personnel during operation; – equipment intended to be used with separate portable or temporary shielding; – equipment intended to produce an emerging beam of X-radiation. 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following new text to the end of the first paragraph: This part of IEC 61010 specifies requirements for the design and methods of construction of cabinet X-ray systems to provide adequate protection for OPERATORS, bystanders, trained service personnel and the surrounding area against unintentionally-emitted X-radiation and from mechanical HAZARDS related to their conveyors.

Required fields are indicated with *

*
*
*
PDF
1.83 € incl tax
Paper
1.83 € incl tax
Standard monitoring