Skip to main content
Back

IEC 60079-31:2022

Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"

General information

Valid from 17.01.2022
Directives or regulations
None

Standard history

Status
Date
Type
Name
31.10.2023
Corrigendum
17.01.2022
Main
IEC 60079-31:2022 is applicable to equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of Ex Equipment and Ex Components. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This document does not apply to dusts of explosives, which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This document does not apply to Ex Equipment or Ex Components intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This document does not take account of any risk due to an emission of flammable or toxic gas from the dust. This third edition cancels and replaces the second edition published in 2013. This edition constitutes a technical revision. Main significant changes from the previous edition are:
1) Document has been restructured from edition 2
2) Fault current rating of interrupting contacts in clauses 4.3.1 and 4.4.1, major change type C1
3) Cells and batteries in clauses 4.3.5.1 and 4.4.5.1, major change type C2
4) Overload or malfunction condition for the determination of temperature class for "tb" converter fed rotating electric machines, major change type C3
5) Additional requirements for entry devices with dust ignition protection by enclosure "t", major change type C4
Information about the background of ‘Major Technical Changes’
C1 – Ex Equipment having Level of Protection "ta" shall be rated for connection to a circuit with a prospective short circuit current of not greater than 1.5 kA. For Ex Equipment having Level of Protection "tb" or "tc" which is intended for mains connection and intended to interrupt fault current above 10kA, the equipment shall have a rated maximum short circuit withstand current, be tested according to 6.1.1.1, and be marked according to Clause 7.
C2 – For Ex Equipment having Level of Protection "ta" which contains a cell or battery, only a sealed cell or battery shall be used. For Ex Equipment having Level of Protection "tb" and "tc" where there are sparking contacts or hot surfaces, and which contains a cell or battery, only a sealed cell or battery shall be used.
C3 – Table 2 now includes malfunction conditions for temperature class determination of Level of Protection "tb" converter-fed electric machines.
C4 – Annex A added for entry devices with Type of Protection "t" including cable transit devices.

Required fields are indicated with *

*
*
*
PDF
150.78 € incl tax
PDF redline
211.09 € incl tax
Paper
150.78 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN IEC 60079-15:2019

Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
Newest version Valid from 02.05.2019
Main + amendment

EVS-EN IEC 60947-5-2:2020+A11:2022

Low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches (IEC 60947-5-2:2019)
Newest version Valid from 17.05.2022
Main

EVS-EN ISO 15609-5:2011

Specification and qualification of welding procedures for metallic materials - Welding procedure specification - Part 5: Resistance welding (ISO 15609-5:2011, Corrected version 2011-12-01)
Newest version Valid from 02.11.2011
Main

EVS-EN ISO 228-1:2003

Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation
Newest version Valid from 01.07.2003