Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements

General information

Valid from 10.01.2017
Directives or regulations
None

Standard history

Status
Date
Type
Name
IEC 61010-1:2010+A1:2016 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.
a) Electrical test and measurement equipment
b) Electrical industrial process-control equipment
c) Electrical laboratory equipment
This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as well as numerous other changes.
- The scope of the standard has been expanded to include all locations where these products may be used, so that both professional and non-professional versions of these products are within the scope.
- The requirements for testing and measuring circuits (in various subclauses and the entirety of Clause 16) have been removed and included in a particular standard IEC 61010-2-030.
- Insulation requirements (6.7) have been completely rewritten.
- Additional requirements for protection against mechanical HAZARDS (Clause 7) have been included.
- Surface temperature limits (Clause 10) have been modified to conform to the limits of EN 563.
- Radiation requirements (Clause 12) have been modified, and take into account a distinction between intended emission and unintended emission.
- Requirements for reasonably foreseeable misuse and ergonomic aspects have been added (Clause 16).
- A new clause (Clause 17) has been added to deal with HAZARDS and environments not covered by the standard, along with a new informative annex (Annex J) dealing with RISK assessment.
- A new informative annex (Annex E) addresses methods of reducing the POLLUTION DEGREE of a micro-environment.
- Requirements for the qualification of coatings for protection against POLLUTION have been added (Annex H).
- A new informative annex (Annex I) has been added to further explain how to determine the WORKING VOLTAGE of a MAINS CIRCUIT.
It has the status of a horizontal standard in accordance with IEC Guide 104. The contents of the corrigendum 1 of May 2011, the interpretation sheet 1 of February 2013 and the corrigendum 2 of October 2013 have been included in this copy.
This consolidated version consists of the third edition (2010) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.

Required fields are indicated with *

*
*
*
PDF
1533.99 € incl tax
Standard monitoring

Customers who bought this item also bought

Main + amendment

EVS-EN ISO 13485:2016+A11:2021

Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)
Newest version Valid from 16.09.2021
Main

EVS-EN ISO 15223-1:2021

Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements (ISO 15223-1:2021)
Valid from 01.10.2021
Main + amendment

EVS-EN 62133-2:2017+A1:2021

Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems (IEC 62133-2:2017 + IEC 62133-2:2017/AMD1:2021)
Newest version Valid from 01.10.2021
Main + amendment

EVS-EN ISO 14971:2019+A11:2021

Medical devices - Application of risk management to medical devices (ISO 14971:2019)
Newest version Valid from 15.12.2021