Skip to main content
Back

ISO 16889:2022

Hydraulic fluid power — Filters — Multi-pass method for evaluating filtration performance of a filter element

General information

Valid from 25.01.2022
Directives or regulations
None

Standard history

Status
Date
Type
Name
25.01.2022
Main
28.11.2018
Amendment
03.06.2008
Main
This document describes the following:
—    a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;
NOTE 1   For the background interlaboratory study used to verify the test methodology, see Annex D.
—    a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;
—    a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L;
NOTE 2   It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.
—    a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A.
This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.
This document applies to three test conditions:
—    test condition 1, with a base upstream gravimetric level of 3 mg/L;
—    test condition 2, with a base upstream gravimetric level of 10 mg/L;
—    test condition 3, with a base upstream gravimetric level of 15 mg/L.