Back

EVS-EN 60947-2:2017

Low-voltage switchgear and controlgear - Part 2: Circuit-breakers (IEC 60947-2:2016 + COR1:2016)

General information
Valid from 18.12.2017
Base Documents
IEC 60947-2:2016; IEC 60947-2:2016/COR1:2016; EN 60947-2:2017
Directives or regulations
2014/35/EU Low voltage (LVD)

Standard history

Status
Date
Type
Name
Main
prEN IEC 60947-2:2022
17.02.2020
Amendment
17.02.2020
Main + amendment
18.12.2017
Main
04.08.2014
Main + amendment
04.06.2013
Amendment
06.11.2012
Main + amendment
08.10.2009
Amendment
06.10.2006
Main
This part of IEC 60947 series applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers.
Circuit-breakers rated above 1 000 V a.c. but not exceeding 1 500 V a.c. may also be testedto this standard.
It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be.
The requirements for circuit-breakers which are also intended to provide earth leakage protection are contained in Annex B.
The additional requirements for circuit-breakers with electronic over-current protection are contained in Annex F.
The additional requirements for circuit-breakers for IT systems are contained in Annex H.
The requirements and test methods for electromagnetic compatibility of circuit-breakers are contained in Annex J.
The requirements for circuit-breakers not fulfilling the requirements for over-current protection are contained in Annex L.
The requirements for modular residual current devices (without integral current breaking device) are contained in Annex M.
The requirements and test methods for electromagnetic compatibility of circuit-breaker auxiliaries are contained in Annex N.
The requirements and test methods for d.c. circuit-breakers for use in photovoltaic (PV) applications are contained in Annex P.
The requirements and test methods for circuit-breakers incorporating residual current protection with automatic reclosing functions are contained in Annex R.
Supplementary requirements for circuit-breakers used as direct-on-line starters are given in IEC 60947-4-1, applicable to low-voltage contactors and starters.
The requirements for circuit-breakers for the protection of wiring installations in buildings and similar applications, and designed for use by uninstructed persons, are contained in IEC 60898.
The requirements for circuit-breakers for equipment (for example electrical appliances) are contained in IEC 60934.
For certain specific applications (for example traction, rolling mills, marine service) particular or additional requirements may be necessary.
NOTE Circuit-breakers which are dealt with in this standard can be provided with devices for automatic opening under predetermined conditions other than those of over-current and undervoltage as, for example, reversal of power or current. This standard does not deal with the verification of operation under such pre-determined conditions.
The object of this standard is to state:
a) the characteristics of circuit-breakers;
b) the conditions with which circuit-breakers shall comply with reference to:
1) operation and behaviour in normal service;
2) operation and behaviour in case of overload and operation and behaviour in case of short-circuit, including co-ordination in service (selectivity and back-up protection);
3) dielectric properties;
c) tests intended for confirming that these conditions have been met and the methods to be adopted for these tests;
d) information to be marked on or given with the apparatus.
*
*
*
PDF
56.12 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN 61010-1:2010/A1:2019

Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
Newest version Valid from 01.03.2019
Amendment

EVS-EN 60335-2-95:2015/A2:2019

Household and similar electrical appliances - Safety - Part 2-95: Particular requirements for drives for vertically moving garage doors for residential use
Withdrawn from 01.06.2023
Amendment

EVS-EN 60335-2-12:2003/A2:2019

Household and similar electrical appliances - Safety - Part 2-12: Particular requirements for warming plates and similar appliances
Newest version Valid from 15.08.2019
Main

EVS-EN IEC 60947-4-1:2019

Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
Newest version Valid from 01.04.2019