Back

EVS-EN IEC 60947-4-1:2019

Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters

General information
Valid from 01.04.2019
Base Documents
IEC 60947-4-1:2018; EN IEC 60947-4-1:2019

Standard history

Status
Date
Type
Name
Main
prEN IEC 60947-4-1:2022
17.05.2021
Corrigendum
02.06.2020
Corrigendum
01.04.2019
Main
06.11.2012
Amendment
07.06.2010
Main
IEC 60947-4-1:2018 is applicable to the following equipment:
- electromechanical contactors and starters including motor protective switching device (MPSD);
- actuators of contactor relays;
- contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;
- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);
intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2009 and its Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Scope structure and exclusions
- Editorial correction of notes and hanging paragraphs
- Reference to IEC 62683-1
- Motor protective switching device (MPSD) with its requirements
- Safety aspects related to:
- General aspects;
- Limited energy circuits;
- Electronic circuits;
- Assessment procedure for electromechanical overload protection used in safety -applications (new Annex L)
- Introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class
- Mention of dedicated wiring accessories
- Pickup power measurement
- Alignment to IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010, and IEC 60947‑1:2007/AMD2:2014
- Direct current requirements for covering photovoltaic application (new Annex M)
- Load monitoring indicators (new Annex O)
- Short-circuit breaking tests of MPSD (new Annex P)
- Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit (new Annex Q).
*
*
*
PDF
46.36 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 60947-5-1:2017

Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices
Newest version Valid from 02.01.2018
Main

EVS-EN 60947-2:2017

Low-voltage switchgear and controlgear - Part 2: Circuit-breakers (IEC 60947-2:2016 + COR1:2016)
Valid from 18.12.2017
Amendment

EVS-EN 60335-2-13:2010/A1:2019

Household and similar electrical appliances - Safety - Part 2-13: Particular requirements for deep fat fryers, frying pans and similar appliances
Newest version Valid from 15.08.2019
Amendment

EVS-EN 60335-2-70:2003/A2:2019

Household and similar electrical appliances - Safety - Part 2-70: Particular requirements for milking machines
Newest version Valid from 16.07.2019