Back

EVS-EN 60947-5-1:2004/A1:2009

Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices

General information
Withdrawn from 02.01.2018
Base Documents
IEC 60947-5-1:2003/A1:2009; EN 60947-5-1:2004/A1:2009

Although the standard’s status is withdrawn, it still has the presumption of conformity in the meaning of regulation 2014/30/EU and conformance with the regulation ’s requirements can be guaranteed by using the withdrawn version of the standard. The presumption of conformity is valid until a corresponding amendment is published in the Official Journal of the European Union.
 
To view the latest lists of harmonised standards published in the Official Journal of the European Union, visit: 
http://ec.europa.eu/growth/single-market/european-standards/harmonised-standards/

Standard history

Status
Date
Type
Name
02.01.2018
Main
07.08.2009
Amendment
09.08.2004
Main
Applies to control circuit devices and switching elements intended for control-ling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c. This standard applies to specific types of control circuit devices such as: - manual control switches, for example pushbuttons, rotary switches, foot switches, etc.; - electromagnetically operated control switches, either time-delayed or instantaneous, for example contactor relays; - pilot switches, for example pressure switches, temperature sensitive switches (thermostats), programmers, etc.; - position switches, for example control switches operated by part of a machine or mechanism; - associated control circuit equipment, for example indicator lights, etc. It also applies to specific types of switching elements associated with other devices (whose main circuits are covered by other standards) such as: - auxiliary contacts of a switching device (e.g. contactor, circuit breaker. etc.) which are not dedicated exclusively for use with the coil of that device; - interlocking contacts of enclosure doors; - control circuit contacts of rotary switches; - control circuit contacts of overload relays. Contactor relays shall also meet the requirements and tests of IEC 60947-4-1 except for the utilization category which shall comply with this standard.
*
*
*
PDF
13.42 € incl tax
Paper
13.42 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 60947-5-1:2004

Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices
Withdrawn from 02.01.2018
Main

EVS-EN 60947-4-1:2010

Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
Withdrawn from 01.04.2019
Main + amendment

EVS-EN 60947-1:2008+A1:2011

Low-voltage switchgear and controlgear - Part 1: General rules (IEC 60947-1:2007, modified + A1:2010)
Withdrawn from 15.03.2021
Main

EVS-EN 60947-3:2009

Low-voltage switchgear and controlgear -- Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units
Withdrawn from 01.03.2021