EVS-EN 62271-107:2012

High-voltage switchgear and controlgear - Part 107: Alternating current fused circuit-switchers for rated voltages above 1 kV up to and including 52 kV

General information
Withdrawn from 01.08.2019
Base Documents
IEC 62271-107:2012; EN 62271-107:2012
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.08.2019
Main
05.09.2012
Main
Main
EVS-EN 62271-107:2005
Subclause 1.1 of IEC 62271-1:2007 is not applicable, and is replaced as follows. This part of IEC 62271 applies to three-pole operated units for distribution systems that are functional assemblies of a circuit-switcher and current-limiting fuses designed so as to be capable of: - breaking, at the rated recovery voltage, any load or fault current up to and including the rated short-circuit breaking current; - making, at the rated voltage, circuits to which the rated short-circuit breaking current applies. They are intended to be used for circuits or applications requiring only a normal mechanical and electrical endurance capability. Such applications cover protection of HV/LV transformers for instance, but exclude distribution lines or cables, as well as motor circuits and capacitor bank circuits. Short-circuit conditions with low currents, up to the fused circuit-switcher rated take-over current, are dealt with by supplementary devices (strikers, relays, etc.), properly arranged, tripping the circuit-switcher. Fuses are incorporated in order to ensure that the short-circuit breaking capacity of the device is above that of the circuit-switcher. NOTE 1 In this standard the term "fuse" is used to designate either the fuse or the fuse-link where the general meaning of the text does not result in ambiguity. This standard applies to fused circuit-switchers designed with rated voltages above 1 kV up to and including 52 kV for use on three-phase alternating current systems of either 50 Hz or 60 Hz. Comparison with other existing switching devices is provided in Clause 8. NOTE 2 Other circuit-switchers exist; see reference [1]1. Devices that require a dependent manual operation are not covered by this standard. Fuses are covered by IEC 60282-1. Earthing switches forming an integral part of a circuit-switcher are covered by IEC 62271-102. Installation in enclosure, if any, is covered either by IEC 62271-200 or by IEC 62271-201.
*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 62271-3:2015

High-voltage switchgear and controlgear - Part 3: Digital interfaces based on IEC 61850
Newest version Valid from 08.06.2015
Main + amendment

EVS-EN 60529:2001+A2:2014

Degrees of protection provided by enclosures (IP code) (IEC 60529:1989 + IEC 60529:1989/A1:1999 + IEC 60529:1989/A2:2013)
Newest version Valid from 01.04.2014
Main

EVS-EN 62271-212:2017

High-voltage switchgear and controlgear - Part 212: Compact Equipment Assembly for Distribution Substation (CEADS)
Withdrawn from 01.09.2022
Main

EVS-EN 62271-112:2013

High-voltage switchgear and controlgear -- Part 112: Alternating current high-speed earthing switches for secondary arc extinction on transmission lines
Withdrawn from 16.09.2021