Back

EVS-EN IEC 55015:2019

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

General information
Valid from 15.10.2019
Base Documents
CISPR 15:2018; EN IEC 55015:2019

Standard history

Status
Date
Type
Name
Amendment
EN IEC 55015:2019/prA1:2023
17.10.2022
Main + amendment
19.03.2020
Amendment
15.10.2019
Main
03.05.2017
Main + amendment
08.06.2015
Amendment
EVS-EN 55015:2013/A1:2015
09.09.2013
Main
EVS-EN 55015:2013
This document applies to the emission (radiated and conducted) of radiofrequency disturbances from:
– lighting equipment (3.3.16);
– the lighting part of multi-function equipment where this lighting part is a primary function;
NOTE 1 Examples are lighting equipment with visible-light communication, entertainment lighting.
– UV and IR radiation equipment for residential and non-industrial applications;
– advertising signs;
NOTE 2 Examples are neon tube advertising signs.
– decorative lighting;
– emergency signs.
Excluded from the scope of this document are:
– components or modules intended to be built into lighting equipment and which are not user-replaceable;
NOTE 3 See CISPR 30 (all parts) for built-in controlgear.
– lighting equipment operating in the ISM frequency bands (as defined in Resolution 63 (1979) of the ITU Radio Regulation);
– lighting equipment for aircraft and airfield facilities (runways, service facilities, platforms);
– video signs;
– installations;
– equipment for which the electromagnetic compatibility requirements in the radio-frequency range are explicitly formulated in other CISPR standards, even if they incorporate a builtin lighting function.
NOTE 4 Examples of exclusions are:
– equipment with built-in lighting devices for display back lighting, scale illumination and signaling;
– SSL-displays;
– range hoods, refrigerators, freezers;
– photocopiers, projectors;
– lighting equipment for road vehicles (in scope of CISPR 12).
The frequency range covered is 9 kHz to 400 GHz. No measurements need to be performed at frequencies where no limits are specified in this document.
Multi-function equipment which is subjected simultaneously to different clauses of this document and/or other standards need to meet the provisions of each clause/standard with the relevant functions in operation.
For equipment outside the scope of this document and which includes lighting as a secondary function, there is no need to separately assess the lighting function against this document, provided that the lighting function was operative during the assessment in accordance with the applicable standard.
*
*
*
PDF
31.72 € incl tax
PDF redline
41.24 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN IEC 55015:2019/A11:2020

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
Valid from 19.03.2020
Main

EVS-EN 61547:2009

Equipment for general lighting purposes - EMC immunity requirements
Withdrawn from 02.05.2023
Main + amendment

EVS-EN 61000-3-3:2013+A1:2019

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection (IEC 61000-3-3:2013 + IEC 61000-3-3:2013/A1:2017)
Valid from 15.08.2019
Amendment

EVS-EN 55016-2-3:2017/A1:2019

Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
Valid from 01.10.2019