Back

EVS-EN IEC 60601-2-19:2021

Medical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators

General information
Valid from 03.08.2021
Base Documents
IEC 60601-2-19:2020; EN IEC 60601-2-19:2021
Directives or regulations
None

Standard history

Status
Date
Type
Name
29.12.2023
Amendment
03.08.2021
Main
03.01.2017
Amendment
02.11.2011
Amendment
07.08.2009
Main
IEC 60601-2-19:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT INCUBATORS, as defined in 201.3.209, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. IEC 60601-2-19:2020 specifies safety requirements for INFANT INCUBATORS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
IEC 60601-2-19:2020 does not apply to:
- INFANT TRANSPORT INCUBATORS; for information, see IEC 60601-2-20;
- INFANT RADIANT WARMERS; for information, see IEC 60601-2-21;
- devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;
- INFANT PHOTOTHERAPY EQUIPMENT; for information see IEC 60601-2-50.
SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED INCUBATOR including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56. IEC 60601-2-19:2020 cancels and replaces the second edition published in 2009 and Amendment 1:2016. This edition constitutes a technical revision. IEC 60601-2-19:2020 includes the following significant technical change with respect to the previous edition: re-dating of normative references.
*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN IEC 60601-2-20:2020

Medical electrical equipment - Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators
Newest version Valid from 15.10.2020
Main

EVS-EN IEC 60601-2-21:2021

Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers
Valid from 03.08.2021
Amendment

EVS-EN 60601-1:2006/A2:2021

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance (IEC 60601-1:2005/A2:2020)
Valid from 01.11.2021
Main

EVS-EN ISO 80601-2-74:2021

Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipment (ISO 80601-2-74:2021)
Newest version Valid from 03.08.2021