EVS-EN IEC 60601-2-21:2021+A1:2023

Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (IEC 60601-2-21:2020 + IEC 60601-2-21:2020/AMD1:2023)

General information

Valid from 17.01.2024
Base Documents
IEC 60601-2-21:2020; EN IEC 60601-2-21:2021; IEC 60601-2-21:2020/AMD1:2023; EN IEC 60601-2-21:2021/A1:2023
Directives or regulations
None

Standard history

Status
Date
Type
Name
17.01.2024
Main + amendment
29.12.2023
Amendment
03.08.2021
Main
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard.
NOTE See also 4.2 of the general standard.
This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
This particular standard does not apply to:
•  devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;
•  INFANT INCUBATORS; for information, see IEC 60601-2-19;
•  INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20;
•  INFANT PHOTOTHERAPY EQUIPMENT, for information, see IEC 60601-2-50.
SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED RADIANT WARMER including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Amendment

EVS-EN 60601-2-37:2008/A1:2015

Medical electrical equipment - Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment
Newest version Valid from 02.09.2015
Amendment

EVS-EN 60601-2-52:2010/A1:2015

Medical electrical equipment - Part 2-52: Particular requirements for the basic safety and essential performance of medical beds
Newest version Valid from 08.06.2015
Amendment

EVS-EN 60601-2-8:2015/A1:2016

Medical electrical equipment - Part 2-8: Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV
Newest version Valid from 03.02.2016
Amendment

EVS-EN 60601-2-10:2015/A1:2016

Medical electrical equipment - Part 2-10: Particular requirements for the basic safety and essential performance of nerve and muscle stimulators
Newest version Valid from 03.01.2017