EVS-EN IEC 61238-1-3:2019

Compression and mechanical connectors for power cables - Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV) tested on non-insulated conductors

General information
Valid from 01.10.2019
Base Documents
IEC 61238-1-3:2018; EN IEC 61238-1-3:2019
Directives or regulations
None
Standard history
Status
Date
Type
Name
01.10.2019
Main
01.10.2019
Amendment
06.04.2006
Main
This part of EN 61238 applies to compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV), for example buried cables or cables installed in buildings, having a) conductors complying with EN 60228 having nominal cross-sectional areas between 2,5 mm2 and 1 200 mm2 for copper and between 16 mm2 and 1 200 mm2 for aluminium, excluding Milliken conductors; b) a maximum continuous conductor temperature not exceeding 90 °C. This document is not applicable to connectors for overhead line conductors nor to connectors with a sliding contact. The object of this document is to define the type test methods and requirements which apply to compression and mechanical connectors for power cables with copper or aluminium conductors. The reference method is to perform the tests on unused conductors.
*
*
*
PDF
19.32 € incl tax
Paper
19.32 € incl tax
Price: 2.40 € incl tax
Standard monitoring
Customers who bought this item also bought
Main

EVS-EN IEC 61238-1-1:2019

Compression and mechanical connectors for power cables - Part 1-1: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on non-insulated conductors
Newest version Valid from 01.10.2019
Amendment

EVS-EN IEC 61238-1-3/A11:2019

Compression and mechanical connectors for power cables - Part 1-3: Test methods and requirements for compression and mechanical connectors for power cables for rated voltages above 1 kV (Um = 1,2 kV) up to 36 kV (Um = 42 kV) tested on non-insulated conductors
Newest version Valid from 01.10.2019
Main

EVS-EN IEC 61238-1-2:2019

Compression and mechanical connectors for power cables - Part 1-2: Test methods and requirements for insulation piercing connectors for power cables for rated voltages up to 1 kV (Um = 1,2 kV) tested on insulated conductors
Newest version Valid from 01.10.2019
Main

EVS-EN 60068-2-30:2006

Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Newest version Valid from 07.09.2006