EVS-EN IEC 61803:2020

Determination of power losses in high-voltage direct current (HVDC) converter stations with line-commutated converters

General information

Valid from 15.12.2020
Base Documents
EN IEC 61803:2020; IEC 61803:2020
Directives or regulations
None

Standard history

Status
Date
Type
Name
Main
prEN IEC 61803:2025
15.12.2020
Main
01.11.2016
Amendment
05.04.2011
Main
05.04.2011
Amendment
IEC 61803:2020 applies to all line-commutated high-voltage direct current (HVDC) converter stations used for power exchange (power transmission or back-to-back installation) in utility systems. This document presumes the use of 12-pulse thyristor converters but can, with due care, also be used for 6-pulse thyristor converters. In some applications, synchronous compensators or static var compensators (SVC) may be connected to the AC bus of the HVDC converter station. The loss determination procedures for such equipment are not included in this document. This document presents a set of standard procedures for determining the total losses of an HVDC converter station. The procedures cover all parts, except as noted above, and address no-load operation and operating losses together with their methods of calculation which use, wherever possible, measured parameters. Converter station designs employing novel components or circuit configurations compared to the typical design assumed in this document, or designs equipped with unusual auxiliary circuits that could affect the losses, are assessed on their own merits. This edition includes the following significant technical changes with respect to the previous edition: - to facilitate the application of this document and to ensure its quality remains consistent, 5.1.8 and 5.8 have been reviewed, taking into consideration that the present thyristor production technology provides considerably less thyristor parameters dispersion comparing with the situation in 1999 when the first edition of IEC 61803 was developed, and therefore the production records of thyristors can be used for the power losses calculation; - the calculation of the total station load losses (cases D1 and D2 in Annex C) has been corrected.

Required fields are indicated with *

*
*
*
PDF
27.28 € incl tax
Paper
27.28 € incl tax
Browse standard from 2.48 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 10279:2000

Hot rolled steel channels - Tolerances on shape, dimensions and mass
Newest version Valid from 01.08.2000
Main

EVS-EN 60940:2015

Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression
Newest version Valid from 08.06.2015
Amendment

IEC TR 60943:1998/AMD1:2008

Amendment 1 - Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals
Newest version Valid from 09.12.2008
Main

EVS-IEC 60050-195:2021

International Electrotechnical Vocablary (IEV) - Part 195: Earthing and protection against electric shock (IEC 60050-195:2021, identical)
Newest version Valid from 31.12.2021