Skip to main content
Back

EVS-EN IEC 62232:2025

Determination of RF field strength, power density and SAR in the vicinity of base stations for the purpose of evaluating human exposure

General information

Valid from 01.07.2025
Base Documents
IEC 62232:2025; EN IEC 62232:2025
Directives or regulations
None

Standard history

Status
Date
Type
Name
01.07.2025
Main
01.12.2022
Main
IEC 62232:2025 provides methods for the determination of RF field strength, power density and specific absorption rate (SAR) in the vicinity of base stations (BS) for the purpose of evaluating human exposure.

This document:

a) considers intentionally radiating BS which transmit on one or more antennas using one or more frequencies in the range 110 MHz to 300 GHz;

b) considers the impact of ambient sources on RF exposure at least in the 100 kHz to 300 GHz frequency range;

c) specifies the methods to be used for RF exposure evaluation for compliance assessment applications, namely:

1) product compliance – determination of compliance boundary information for a BS product before it is placed on the market;

2) product installation compliance – determination of the total RF exposure levels in accessible areas from a BS product and other relevant sources before the product is put into operation;

3) in-situ RF exposure assessment – measurement of in-situ RF exposure levels in the vicinity of a BS installation after the product has been taken into operation;

d) specifies how to perform RF exposure assessment based on the actual maximum approach;

e) describes several RF field strength, power density, and SAR measurement and computation methodologies with guidance on their applicability to address both the in-situ evaluation of installed BS and laboratory-based evaluations;

f) describes how surveyors establish their specific evaluation procedures appropriate for their evaluation purpose;

g) provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value;

h) provides methods for the RF exposure assessment of BS using time-varying beam-steering technologies such as new radio (NR) BS using massive multiple input multiple output (MIMO).

NOTE 1 Practical implementation case studies are provided as examples in the companion Technical Report IEC TR 62669 [5].

NOTE 2 Although the current BS product types have been specified to operate up to 200 GHz (see, for example, [6] and [7]), the upper frequency of 300 GHz is consistent with applicable exposure limits.

NOTE 3 The lower frequency considered for ambient sources, 100 kHz, is derived from ICNIRP-1998 [2] and ICNIRP-2020 [1]. However, some applicable exposure guidelines require ambient fields to be evaluated as low as 3 kHz, e.g. Safety Code 6 [4] and IEEE Std C95.1-2019 [3].

NOTE 4 Specification of appropriate RF exposure mitigation measures such as signage, access control, and training are beyond the scope of this document. It is possible to refer to the applicable regulations or recommended practices on these topics.

NOTE 5 While this document is based on the current international consensus about the best engineering practice for assessing the compliance of RF exposure with the applicable exposure limits, it is possible that national regulatory agencies specify different requirements. The entity conducting an RF exposure assessment needs to be aware of the applicable regulations.

This fourth edition cancels and replaces the third edition published in 2022. It includes corrections of obvious errors and text improvements on the third edition in order to bring more clarity in the description of the assessment methods and avoid misinterpretations. This edition has the same technical content as the third edition.

Required fields are indicated with *

*
*
*
PDF
57.04 € incl tax
Browse standard from 2.48 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 14644-5:2025

Cleanrooms and associated controlled environments - Part 5: Operations (ISO 14644-5:2025)
Newest version Valid from 15.09.2025
Main + amendment

EVS-EN ISO 10993-17:2023+A1:2025

Biological evaluation of medical devices - Part 17: Toxicological risk assessment of medical device constituents (ISO 10993-17:2023 + ISO 10993-17:2023/Amd 1:2025)
Newest version Valid from 15.01.2026
Main + amendment

EVS-EN 60601-1-2:2015+A1:2021

Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and tests (IEC 60601-1-2:2014 + IEC 60601-1-2:2014/A1:2020)
Newest version Valid from 01.04.2021
Main + amendment

EVS-EN 60601-1-11:2015+A1:2021

Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment (IEC 60601-1-11:2015 + IEC 60601-1-11:2015/A1:2020)
Newest version Valid from 17.08.2021