Skip to main content
Back

IEC 60332-2-2:2004

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

General information

Valid from 15.07.2004
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.07.2004
Main
Specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in IEC 60332-2-1.
This standard gives the procedure for testing small optical fibre cables or a small insulated conductor or cable when the method specified in IEC 60332-1-2 is not suitable because some small optical fibre cables may break or small conductors may melt during the application of the flame. The recommended range of application is for the testing of small single insulated conductors or cables of less than 0,5 mm² cross-section.
NOTE Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example, in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)
Recommended requirements for performance are given in Annex A.
Has the status of a group safety publication in accordance with IEC Guide 104.

Required fields are indicated with *

*
*
*
PDF
106.71 € incl tax
Paper
106.71 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

IEC 60332-1-3:2004+AMD1:2015 CSV

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
Newest version Valid from 28.07.2015
Main

IEC TS 60695-11-21:2005

Fire hazard testing - Part 11-21: Test flames - 500 W vertical flame test method for tubular polymeric materials
Newest version Valid from 04.05.2005
Main

IEC 60332-1-2:2004+AMD1:2015 CSV

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
Newest version Withdrawn from 19.06.2025