Skip to main content
Back

IEC 61755-3-2:2024

Fibre optic interconnecting devices and passive components - Connector optical interfaces - Part 3-2: Connector parameters of dispersion unshifted single-mode physically contacting fibres - Angled 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules

General information

Valid from 11.04.2024
Directives or regulations
None

Standard history

Status
Date
Type
Name
11.04.2024
Main
12.01.2009
Corrigendum
12.07.2006
Main
IEC 61755-3-2:2024 defines the dimensional limits of the optical interface that are necessary for single-mode fibre optic connectors with 2,5 mm or 1,25 mm diameter cylindrical zirconia (ZrO2) ferrules polished at an 8° angle to meet the specific requirements for fibre-to-fibre interconnection, as defined in IEC 61755-2-2. Ferrules made from the material specified in this standard are suitable for use in all the operating service environments defined in IEC 61753-1. Ferrule dimensions and features are contained in the IEC 61754 series of fibre optic connector interface standards. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) normative references have been added;
b) The introduction of an additional optical interface with a different fibre core eccentricity profile. The previous revision of optical interface standard is named "Variant 1: with fibre core axis oriented towards the connector guide key".
The additional optical interface is named "Variant 2: with fibre core axis not oriented towards the connector guide key";
c) statements added related to interoperability, where both variants remain intermateable within a given performance grade and are fully backwards compatible to IEC 61755-3-2:2006;
d) The addition of Grade B and Grade C interface requirements for both variants;
f) The addition of a descriptive statistic for the mean fibre core eccentricity (mean value) to describe the distribution of fibre core eccentricity to ensure interoperability;
g) A new informative Annex B to give guidance on the expected attenuation when mated to a reference connector plug;
h) A new informative Annex D to give guidance related to estimation of mean fibre eccentricity limits for finite production batch sizes.

Required fields are indicated with *

*
*
*
PDF
196.66 € incl tax
Paper
196.66 € incl tax
Standard monitoring