Skip to main content
Back

ISO 5660-1:2015

Reaction-to-fire tests -- Heat release, smoke production and mass loss rate -- Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement) (Corrected version 2021-01)

General information

Valid from 20.03.2015
Directives or regulations
None

Standard history

Status
Date
Type
Name
06.08.2019
Amendment
20.03.2015
Main
ISO 5660-1:2015 specifies a method for assessing the heat release rate and dynamic smoke production rate of specimens exposed in the horizontal orientation to controlled levels of irradiance with an external igniter. The heat release rate is determined by measurement of the oxygen consumption derived from the oxygen concentration and the flow rate in the combustion product stream. The time to ignition (sustained flaming) is also measured in this test.
The dynamic smoke production rate is calculated from measurement of the attenuation of a laser light beam by the combustion product stream. Smoke obscuration is recorded for the entire test, regardless of whether the specimen is flaming or not.

Required fields are indicated with *

*
*
*
PDF
254.36 € incl tax
Paper
254.36 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 1366-12:2014

Fire resistance tests for service installations - Part 12: Non-mechanical fire barrier for ventilation ductwork
Withdrawn from 15.11.2019
Amendment

ISO 29767:2008/Amd 1:2014

ISO 29767:2008 - Amendment
Withdrawn from 27.06.2019
Main + corrigendum

EVS-EN 13830:2015

Curtain walling - Product standard
Withdrawn from 02.06.2020
Main + amendment

EVS-EN 13166:2012+A2:2016

Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification
Newest version Valid from 05.07.2016