ISO 5725-3:2023

Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate precision and alternative designs for collaborative studies

General information

Valid from 28.06.2023
Directives or regulations
None

Standard history

Status
Date
Type
Name
28.06.2023
Main
25.10.2001
Corrigendum
22.12.1994
Main
This document provides
a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and
b)    worked examples including specific designs and computations.
Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:
a)    a discussion of the implications of the definitions of intermediate precision measures;
b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;
c)    determining reproducibility, repeatability and selected measures of intermediate precision;
d)    improved determination of reproducibility and other measures of precision;
e)    improving the estimate of the sample mean;
f)     determining the range of in-house repeatability standard deviations;
g)    determining other precision components such as operator variability;
h)    determining the level of reliability of precision estimates;
i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;
j)     avoiding distorted estimations of repeatability (split-level designs);
k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).
Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

Required fields are indicated with *

*
*
*
PDF
254.36 € incl tax
Paper
254.36 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

ISO 11737-3:2023

Sterilization of health care products — Microbiological methods — Part 3: Bacterial endotoxin testing
Newest version Valid from 26.06.2023
Main

ISO 5725-1:2023

Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
Newest version Valid from 20.07.2023
Main

ISO 10993-17:2023

Biological evaluation of medical devices — Part 17: Toxicological risk assessment of medical device constituents
Newest version Valid from 13.09.2023
Amendment

EVS-EN ISO 11607-1:2020/A1:2023

Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems - Amendment 1: Application of risk management (ISO 11607-1:2019/Amd 1:2023)
Valid from 01.11.2023