Skip to main content
Back

Sorry - this product is no longer available

prEN IEC 62304:2021

Health software - Software life cycle processes

General information

Draft
Base Documents
IEC 62304:202X; prEN IEC 62304:2021
Directives or regulations
None

Standard history

Status
Date
Type
Name
Main
prEN IEC 62304:2021
15.11.2019
Main + amendment
04.11.2015
Amendment
03.04.2009
Corrigendum
06.10.2006
Main
1.1 * Purpose This document defines the development and maintenance life cycle requirements for HEALTH SOFTWARE. The set of PROCESSES, ACTIVITIES, and TASKS described in this document establishes a common framework for HEALTH SOFTWARE life cycle PROCESSES. 1.2 * Field of application This document applies to the development and maintenance of HEALTH SOFTWARE by a MANUFACTURER. MEDICAL DEVICE SOFTWARE is a subset of HEALTH SOFTWARE (see Figure 2). Therefore, this document applies to: - software as part of a MEDICAL DEVICE; - software as part of specific health hardware; - software as a MEDICAL DEVICE (SaMD); - software-only product for other health use. Figure 2 provides a graphical representation of the health software this document applies to. [Figure 2] NOTE 1 Examples of HEALTH SOFTWARE include the following: 1) software as a part of a MEDICAL DEVICE: software that is an integral part of a device such as an infusion pump or dialysis machine. 2) software as part of specific health hardware: patient wristband printer software, healthcare scanner software, health app on specific wearable hardware (i.e. watch, wristband, chestband). 3) software as a MEDICAL DEVICE (SaMD): software that is itself a MEDICAL DEVICE, such as a software application that performs diagnostic image analysis for making treatment decisions. A definition of software as a MEDICAL DEVICE is provided in [46] 1. 4) software-only product for other health use: hospital information systems, electronic health records, electronic medical records, mobile applications running on devices without physiologic sensors or detectors, software as a service, i.e. software executed in an external environment, providing calculation-results that fulfil the definition of a MEDICAL DEVICE. NOTE 2 This document can be used in the development and maintenance of HEALTH SOFTWARE. Before any type of software can be placed into service, activities are necessary before the software product is integrated into the SYSTEM. These SYSTEM activities are not covered by this document (see Figure 1), but can be found in related product standards (e.g., IEC 60601-1 [1] or IEC 82304-1 [15]). For software as a MEDICAL DEVICE (SaMD) additional guidance on ACTIVITIES at a system level (e.g. clinical EVALUATION) can be found in regulatory authority guidance documents. [...]

Required fields are indicated with *

*
*
*
PDF
31.42 € incl tax
Paper
31.42 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN IEC 61000-4-3:2020

Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2020)
Newest version Valid from 31.12.2020
Main

EVS-EN ISO 3744:2010

Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
Newest version Valid from 06.12.2010
Main

EVS-EN 61672-1:2013

Electroacoustics - Sound level meters -- Part 1: Specifications
Newest version Valid from 06.01.2014
Main

EVS-EN ISO 10993-4 V2:2017

Biological evaluation of medical devices - Part 4: Selection of tests for interactions with blood (ISO 10993-4:2017)
Newest version Valid from 01.11.2017