This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant.
HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard.
NOTE See also 4.2 of the general standard.
This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device.
This particular standard does not apply to:
•  devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information, see IEC 60601-2-35;
•  INFANT INCUBATORS; for information, see IEC 60601-2-19;
•  INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20;
•  INFANT PHOTOTHERAPY EQUIPMENT, for information, see IEC 60601-2-50.
SKIN TEMPERATURE SENSORS which are applied to operate a BABY CONTROLLED RADIANT WARMER including the displayed value are not considered to be a CLINICAL THERMOMETER in the sense of the particular standard ISO 80601-2-56.

Nõutud väljad on tähistatud *

*
*
*
PDF
26,84 € koos KM-ga
Paber
26,84 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Muudatus

EVS-EN 60601-2-37:2008/A1:2015

Elektrilised meditsiiniseadmed. Osa 2-37: Erinõuded ultraheli meditsiinilise diagnostika- ja seireseadmete esmasele ohutusele ja olulistele toimivusnäitajatele
Uusim versioon Kehtiv alates 02.09.2015
Muudatus

EVS-EN 60601-2-52:2010/A1:2015

Elektrilised meditsiiniseadmed. Osa 2-52: Erinõuded elektriga käitatavate haiglavoodite esmasele ohutusele ja olulistele toimimisnäitajatele
Uusim versioon Kehtiv alates 08.06.2015
Muudatus

EVS-EN 60601-2-8:2015/A1:2016

Elektrilised meditsiiniseadmed. Osa 2-8: Erinõuded vahemikus 10 kV kuni 1 MV töötavate röntgenraviseadmete esmasele ohutusele ja olulistele toimimisnäitajatele
Uusim versioon Kehtiv alates 03.02.2016
Muudatus

EVS-EN 60601-2-10:2015/A1:2016

Elektrilised meditsiiniseadmed. Osa 2-10: Erinõuded närvi- ja lihasstimulaatorite esmasele ohutusele ja olulistele toimimisnäitajatele
Uusim versioon Kehtiv alates 03.01.2017