Tagasi

IEC 60800:2009

Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation

Üldinfo
Kehtetu alates 22.11.2021
Tegevusala (ICS grupid)
29.060.20 Kaablid
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
28.08.2009
Parandus
23.07.2009
Põhitekst
IEC 60800:2009 is applicable to, and specifies requirements for, resistive heating cables for low temperature applications such as comfort heating and the prevention of ice formation. These cables and cable sets may comprise either factory fabricated or field (work-site) assembled units, and which are heating cables assembled in accordance with manufacturer's instructions. Bare conductors and protected conductors to be supplied at voltages equal to, or less than, 50 V are excluded from the scope of this standard. Typical applications include, but are not limited to - surface heating installed in or under surfaces - direct and storage heating - snow melting and frost protection of roofs, gutters, pipes, etc. Heating cables for industrial and commercial applications are specified in the IEC 62395 series as are mineral insulated heating cables. Applications in which the operating sheath temperature exceeds 100 °C are outside the scope of this standard. The object of this standard is to ensure that electrical resistance heating cables operate safely under their normal defined conditions of use. This is achieved by: - employing heating cables of the appropriate construction that meet the test criteria detailed in this standard
- including, for cables with an electrical protective component, a metallic braid, concentric wires or sheath, or other suitable electrically conductive material for protective purposes in case of fault - ensuring that the cables operate at safe temperatures with respect to the materials used in the construction of the cables and their installations according to national regulations. The significant technical changes with respect to the previous edition are as follows: - introduction of heating cable sets
- testing of heating cable sets, including the integrated cold-lead, cold-lead splice and end-termination in twin and multicore cable sets, in addition to the heating cable - introduction of requirements for installation instructions - reduction to two, instead of three, mechanical classes, one for cables intended for installation with a low risk of mechanical damage (M1) and one for cables intended for installation with a higher risk of mechanical damage (M2) - elimination of reference to specific materials to be used as insulation and sheath - introduction of routine and sample tests.
*
*
*
PDF
249,11 € koos KM-ga
Paber
249,11 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Muudatus

EVS-EN 50085-1:2005/A1:2013

Elektripaigaldiste kaablirenni- ja kaablitorusüsteemid. Osa 1: Üldnõuded
Uusim versioon Kehtiv alates 05.08.2013
Muudatus

EVS-EN 50085-2-1:2006/A1:2011

Elektripaigaldiste kaablirenni- ja kaablitorusüsteemid. Osa 2-1: Seinale ja lakke paigaldatavad kaablirenni- ja kaablitorusüsteemid
Uusim versioon Kehtiv alates 02.11.2011
Põhitekst

EVS-EN 50085-2-2:2008

Elektripaigaldiste suletud ja avatavate kaablikarbikute süsteemid. Osa 2-2: Erinõuded põrandaalustele, põrandasse süvistatud ja põrandapealsetele suletud ja avatavate kaablikarbikute süsteemidele
Uusim versioon Kehtiv alates 09.01.2009