CLC/TS 50568-8:2015

Electricity metering data exchange - The DLMS/COSEM suite - Part 8: SMITP B-PSK PLC communication profile for neighbourhood networks - Including: The Original-SMITP PLC B-PSK communication profile, The Original-SMITP Local data exchange profile and The Original-SMITP IP communication profile

Üldinfo

Kehtiv alates 07.05.2015
Alusdokumendid
CLC/TS 50568-8:2015
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
07.05.2015
Põhitekst
This Technical Specification contains 4 profile specifications:
•  the DLMS/COSEM SMITP B-PSK PLC Profile (clause 4)
•  the Original-SMITP B-PSK PLC Profile (clause 5)
•  the Original-SMITP IP Profile (clause 6)
•  the Original-SMITP Local data exchange profile (clause 7)
The DLMS/COSEM SMITP B-PSK profile defines the use of the CLC/FprTS 50568-4 communication protocol and methods to access and exchange data modelled by the COSEM objects of EN 62056 6 2 via the EN 62056-5-3 application layer. This section forms part of the DLMS/COSEM suite as described in FprEN 62056-1-0.
NOTE  In the following, the expression Original-SMITP refers to the open protocol originally developed and maintained by the Meters and More Open Technologies association (see Foreword).
The Original-SMITP Profiles define the access and exchange of data modelled by the Original-SMITP data model (clause 9) using the Original-SMITP application services (Clause 8).
The “Original-SMITP” specifications refer to smart metering system specifications defined prior to the availability of the DLMS/COSEM SMITP B-PSK PLC Profile. The “Original-SMITP” specifications do not form part of the DLMS/COSEM suite of EN 62056.

Nõutud väljad on tähistatud *

*
*
*
PDF
56,12 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

CLC/TS 52056-8-5:2015

Electricity metering data exchange - The DLMS/COSEM suite - Part 8-5: Narrow-band OFDM G3-PLC communication profile for neighbourhood networks
Kehtetu alates 17.11.2017
Põhitekst

CLC/TS 52056-8-4:2015

Electricity metering data exchange - The DLMS/COSEM suite - Part 8-4: Narrow-band OFDM PRIME PLC communication profile for neighbourhood networks
Uusim versioon Kehtetu alates 01.11.2019
Põhitekst

EVS-EN 62056-7-5:2016

Electricity metering data exchange - The dlms/cosem suite - Part 7-5: Local data transmission profiles for Local Networks (LN)
Uusim versioon Kehtiv alates 03.01.2017
Põhitekst

EVS-EN 61869-6:2016

Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers
Uusim versioon Kehtiv alates 03.01.2017