Skip to main content
Back

EVS-EN 16361:2013

Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics

General information

Withdrawn from 03.08.2016
Base Documents
EN 16361:2013
Directives or regulations
None

Standard history

Status
Date
Type
Name
03.08.2016
Main + amendment
14.11.2013
Main
This European Standard specifies requirements and test/assessment/calculation methods for external and
internal power operated pedestrian doorsets, other than swing type, initially designed for installation with
power operation without resistance to fire and smoke leakage characteristics.
Such doorset constructions may be operated electro-mechanically, electro-hydraulically or pneumatically.
These doorsets include power operated pedestrian sliding doorsets, revolving doorsets, balanced
(sliding/swing) doorsets and folding doorsets with one or more horizontally moving leaves.
This European Standard applies to power operated pedestrian doorsets with flush or panelled leaves,
complete with:
 integral fanlights, if any;
NOTE 1 A fanlight is a panel over a door which is part of the doorset.
 side panels that are contained within a single frame for inclusion in a single aperture, if any.
The intended uses of the products covered by this European Standard are:
 doorsets for external use in escape routes and other declared specific uses and/or uses subject to other
specific requirements, in particular noise, energy, tightness and safety-in-use in construction works;
 doorsets for internal use in escape routes, communication and other declared specific uses and/or uses
subject to other specific requirements, in particular noise and safety-in-use in construction works;
 doorsets for internal use in escape routes, communication and other declared specific uses and/or uses
subject to other specific requirements, in particular noise, energy and safety-in-use in construction works.
The products covered by this European Standard are not assessed for structural applications of the building.
This European Standard does not cover operation in environments where the electromagnetic disturbances
are outside the range of those specified in EN 61000-6-2.
This European Standard does not apply to:
 external pedestrian doorsets according to EN 14351-1;
 internal pedestrian doorsets according to prEN 14351-2;
 fire resistant and/or smoke control doorsets according to prEN 16034;
 industrial, commercial and garage doors and gates according to EN 13241-1;
 lifts doorsets;
 vehicles doorsets;
 doorsets used in industrial processes;
 doorsets in partition walls;
 doorsets outside the reach of people (such as crane gantry fences);
 turnstiles;
 platform doorsets.
This European Standard does not cover special functions of doorsets (e.g. security, fire aspects in banks,
airports, etc.).
This European Standard does not deal with any specific requirements on noise emitted from power operated
doorsets, other than swing type, initially designed for installation with power operation without resistance to
fire and smoke leakage characteristics as their noise emission is not considered to be a relevant hazard.
NOTE 2 Noise emission of power operated doorsets, other than swing type, initially designed for installation with power
operation without resistance to fire and smoke leakage characteristics is not a significant hazard for the users of these
products. It is a comfort aspect.

Required fields are indicated with *

*
*
*
PDF
26.84 € incl tax
Paper
26.84 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 10346:2015

Continuously hot-dip coated steel flat products for cold forming - Technical delivery conditions
Newest version Valid from 04.11.2015
Main + corrigendum

EVS-EN 13830:2015

Curtain walling - Product standard
Withdrawn from 02.06.2020
Main

EVS-EN 1627:2011

Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification
Withdrawn from 20.07.2021
Main

EVS-EN 1670:2007

Building hardware - Corrosion resistance - Requirements and test methods
Newest version Valid from 06.06.2007