Back

EVS-EN 61000-4-5:2014/A1:2017

Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

General information
Valid from 01.12.2017
Base Documents
IEC 61000-4-5:2014/A1:2017; EN 61000-4-5:2014/A1:2017
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.11.2019
Main + amendment
01.12.2017
Amendment
03.09.2014
Main
IEC 61000-4-5 relates to the immunity requirements, test methods, and range of recommended test levels for equipment regarding unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environments and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment.

The object of IEC 61000-4-5 is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in IEC 61000-4-5 describes a consistent method to assess the immunity of equipment or systems against a defined phenomenon.

In this amendment you can find informative Annex I:

— that explains issues relating to powering EUTs having DC/DC converters at the input

— and offers considerations for remediation.

The text of IEC 61000-4-5:2014 has been approved in Europe as EN 61000-4-5:2014 without any changes. The main text and the consolidated version which consists of the main text and the amendment can be found in the standard’s history. EN 61000-4-5:2014/A1:2017 modifies the European standard EN 61000-4-5:2014.
*
*
*
PDF
7.32 € incl tax
Paper
7.32 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 61000-4-5:2014

Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
Valid from 03.09.2014
Main

EVS-EN 61000-4-4:2012

Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4:2012)
Newest version Valid from 05.12.2012
Main

EVS-EN 61000-4-2:2009

Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
Newest version Valid from 04.06.2009
Main

EVS-EN 61000-4-6:2014

Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Withdrawn from 15.08.2023