Back

EVS-EN 61000-4-5:2014+A1:2017

Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test

General information
Valid from 15.11.2019
Base Documents
IEC 61000-4-5:2014; EN 61000-4-5:2014; IEC 61000-4-5:2014/A1:2017; EN 61000-4-5:2014/A1:2017
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.11.2019
Main + amendment
01.12.2017
Amendment
03.09.2014
Main
This part of IEC 61000 relates to the immunity requirements, test methods, and range of recommended test levels for equipment with regard to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for
and are applicable to electrical and electronic equipment.
The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in
this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon.
NOTE As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC.
As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity
test standard is applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the
evaluation of the value of particular immunity test levels for their products.
This standard defines:
– a range of test levels;
– test equipment;
– test setups;
– test procedures.
The task of the described laboratory test is to find the reaction of the equipment under test (EUT) under specified operational conditions to surge voltages caused by switching and lightning effects.
It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress.
Direct injections of lightning currents, i.e. direct lightning strikes, are not considered in this standard.
*
*
*
PDF
33.60 € incl tax
Paper
33.60 € incl tax
Browse standard for 24 hours: 2.40 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN 61000-4-4:2012

Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test (IEC 61000-4-4:2012)
Newest version Valid from 05.12.2012
Main

EVS-EN 61000-4-2:2009

Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
Newest version Valid from 04.06.2009
Main

EVS-EN IEC 61000-4-3:2020

Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2020)
Newest version Valid from 31.12.2020
Main

EVS-EN 61000-4-6:2014

Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
Newest version Valid from 01.04.2014