Skip to main content
Tagasi

EVS-EN 50264-2-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables

Üldinfo

Kehtiv alates 05.09.2008
Alusdokumendid
EN 50264-2-1:2008
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
05.09.2008
Põhitekst
Põhitekst
EN 50264-2-1 specifies requirements for, and constructions and dimensions of, single core cables of the following types and voltage ratings: •  0,6/1 kV unscreened, unsheathed  (1 mm² to 400 mm²); •  1,8/3 kV unscreened, unsheathed  (1,5 mm² to 400 mm²); •  1,8/3 kV unscreened, sheathed  (1,5 mm² to 400 mm²); •  3,6/6 kV unscreened, sheathed  (2,5 mm² to 400 mm²). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.  EN 50264-2-1 should be read in conjunction with Part 1 “General requirements”.

Nõutud väljad on tähistatud *

*
*
*
PDF
19,52 € koos KM-ga
Paber
19,52 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 50264-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-2-2:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-3-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-3-2:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
Uusim versioon Kehtiv alates 05.09.2008