EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: •  300/500 V screened or unscreened  (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40); •  0,6/1 kV screened or unscreened  (1,5 mm² to 50 mm², 2, 3 and 4 cores). All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.
*
*
*
PDF
20,74 € koos KM-ga
Paber
20,74 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN 50264-3-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-3-2:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
Uusim versioon Kehtiv alates 05.09.2008
Põhitekst

EVS-EN 50264-2-1:2008

Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
Uusim versioon Kehtiv alates 05.09.2008