Skip to main content
Tagasi

EVS-EN IEC 60079-29-0:2026

Explosive atmospheres - Part 29-0: Gas detection equipment - General requirements and test methods

Üldinfo

Kehtiv alates 02.02.2026
Alusdokumendid
IEC 60079-29-0:2025; EN IEC 60079-29-0:2026
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
02.02.2026
Põhitekst
17.04.2023
Muudatus
01.06.2022
Põhitekst + muudatus
01.06.2022
Muudatus
01.06.2022
Muudatus
15.11.2019
Põhitekst
03.01.2017
Põhitekst
07.06.2010
Põhitekst
IEC 60079-29-0:2025 specifies general requirements, test methods and acceptance criteria that apply to flammable, oxygen and toxic gas detection equipment intended to detect gases and vapours and to provide an indication, alarm or other output function for personnel or property protection in industrial and commercial applications.
This document applies to the following gas detection equipment:
– Gas detection equipment Type "FL" intended for the detection of flammable gases:
• Type FL-Group I, in mines susceptible to firedamp;
• Type FL-Group II, in locations other than mines susceptible to firedamp; and
• Type FL-OP, open path gas detection equipment for flammable gases.
– Gas detection equipment Type "O2" intended for the detection of Oxygen:
• Type O2-DE, detection of oxygen deficiency or oxygen enrichment; and
• Type O2-IN, inertisation as measuring function for explosion protection.
– Gas detection equipment Type "TX" intended for the detection of toxic gases:
• Type TX-SM, detection in areas for safety monitoring applications and typically using alarm signalling;
• Type TX-HM, occupational exposure measurement in the region of occupational exposure limit values; and
• Type TX-OP, open path gas detection equipment for toxic gases.
This document is not applicable to equipment:
– used for medical applications;
– used only in laboratories for analysis or measurement;
– used only for process monitoring or control purposes (such as a gas analyser);
– used in the domestic environment;
– used in environmental air pollution monitoring;
– used for flue gas analysis;
– used for sampling systems external to the gas detection equipment;
– with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
– consisting of a passive optical receiver without a dedicated optical source;
– equipment within the scope of IEC 60335-2-40 and IEC 60335-2-89.
This first edition of IEC 60079-29-0 cancels and replaces the second edition of 60079-29-1 published in 2016 and its Amendment 1:2020, and the first edition of IEC 60079-29-4 published in 2009. In addition, IEC 60079-29-0 Type TX-SM cancels and replaces Type SM of the first edition of IEC 62990-1.

Nõutud väljad on tähistatud *

*
*
*
PDF
39,68 € koos KM-ga
Paber
39,68 € koos KM-ga
Sirvi standardit alates 2,48 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN ISO 2738:2026

Sintered metal materials, excluding hardmetals - Permeable sintered metal materials - Determination of density, oil content and open porosity (ISO 2738:2026)
Uusim versioon Kehtiv alates 02.02.2026