Skip to main content
Back

EVS-EN ISO 16890-2:2022

Air filters for general ventilation - Part 2: Measurement of fractional efficiency and air flow resistance (ISO 16890-2:2022)

General information

Valid from 15.09.2022
Base Documents
ISO 16890-2:2022; EN ISO 16890-2:2022
Directives or regulations
None

Standard history

Status
Date
Type
Name
15.09.2022
Main
03.01.2017
Main
This document specifies the aerosol production, the test equipment and the test methods used for measuring fractional efficiency and air flow resistance of air filters for general ventilation.
It is intended to be used in conjunction with ISO 16890‑1, ISO 16890‑3 and ISO 16890‑4.
The test method described in this document is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24.0 inches × 24.0 inches).
This document refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined within the ISO 16890 series.
NOTE      The lower limit for this test procedure is set at a minimum ePM10 efficiency of 20 % since it is very difficult for a test filter element below this level to meet the statistical validity requirements of this procedure.
This document is not applicable to filter elements used in portable room-air cleaners.

Required fields are indicated with *

*
*
*
PDF
31.72 € incl tax
Paper
31.72 € incl tax
Browse standard from 2.44 € incl tax
Standard monitoring

Customers who bought this item also bought

Main

EVS-EN ISO 16890-4:2022

Air filters for general ventilation - Part 4: Conditioning method to determine the minimum fractional test efficiency (ISO 16890-4:2022)
Newest version Valid from 15.09.2022
Main

EVS-EN ISO 16276-1:2007

Corrosion protection of steel structures by protective paint systems - Assessment of, and acceptance criteria for, the adhesion/cohesion (fracture strength) of a dry film - Part 1: Pull-off testing
Newest version Valid from 04.07.2007
Main

EVS-EN ISO 16276-2:2007

Corrosion protection of steel structures by protective paint systems - Assessment of, and acceptance criteria for, the adhesion/cohesion (fracture strength) of a dry film - Part 2: Cross-cut test and X-cut testing
Newest version Valid from 04.07.2007
Main

EVS-EN ISO 16890-3:2016

Air filters for general ventilation - Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured (ISO 16890-3:2016)
Newest version Valid from 03.01.2017