Skip to main content
Tagasi

IEC 60079-28:2025

Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation

Üldinfo

Kehtiv alates 21.11.2025
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
21.11.2025
Põhitekst
14.11.2019
Parandus
27.05.2015
Põhitekst
IEC 60079-28:2025 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL).
This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms:
• Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere.
• In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point.
• Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres.
This document applies to
a) laser equipment; and
b) optical fibre equipment; and
c) any optical system that converts light into convergent beams with focal points within the hazardous area only.
This document does not apply to:
d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or
e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables:
1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or
2) comply with the relevant industrial standards for optical fibre cables (for EPL Gc or Dc); or
f) Optical radiation sources as defined in i) to iii) above where the optical radiation is fully contained in an enclosure complying with one of the following Types of Protection suitable for the EPL, or the minimum ingress protection rating specified:
1) flameproof "d" enclosures (IEC 60079-1); or
2) pressurized "p" enclosures (IEC 60079-2); or
3) restricted breathing "nR" enclosure (IEC 60079-15); or
4) dust protection "t" enclosures" (IEC 60079-31); or
5) an enclosure that provides a minimum ingress protection of IP 6X and where no internal absorbers are to be expected and complying with "Tests of enclosures" in IEC 60079-0.
This document does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this document.
This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.
This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision

Nõutud väljad on tähistatud *

*
*
*
PDF
346,82 € koos KM-ga
Paber
346,82 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

IEC 60079-29-0:2025

Explosive atmospheres - Part 29-0: Gas detection equipment - General requirements and test methods
Uusim versioon Kehtiv alates 27.11.2025