EVS-EN ISO 11140-6:2022

Sterilization of health care products - Chemical indicators - Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers (ISO 11140-6:2022)

Üldinfo

Kehtiv alates 15.12.2022
Alusdokumendid
ISO 11140-6:2022; EN ISO 11140-6:2022
Direktiivid või määrused
puuduvad

Standardi ajalugu

Staatus
Kuupäev
Tüüp
Nimetus
15.12.2022
Põhitekst
05.03.2002
Põhitekst
This document specifies the performance requirements and test methods for hollow devices and porous devices as well as the chemical indicators and biological indicators that are utilized within these devices for testing a specific steam penetration performance of type B cycles and some type S cycles of small steam sterilizers according to EN 13060.
NOTE      The hollow and porous devices described in this document are not intended for use as surrogate devices for hollow and porous medical devices used in health care facilities.
a)    Chemical indicators used with a porous device specified in this document are designed to demonstrate the adequacy of steam penetration into a porous device in small steam sterilizers (see EN 13060).
This document specifies the requirements for:
—    a reference porous device (RPD) as a reference device by which alternative porous indicator systems (APISs) can be shown to be equivalent in performance according to this document, i.e. a textile test pack in which steam penetration is judged by thermometric means;
—    an alternative porous chemical indicator system equivalent in performance to the RPD, i.e. an APIS, usually commercially manufactured, of any design.
b)    Chemical indicators used with a hollow load device specified in this document are designed to demonstrate the adequacy of steam penetration into a narrow lumen (previously known as hollow load A) in small steam sterilizers (see EN 13060).
This document specifies the requirements for:
—    a reference hollow device (RHD) used as a reference device in this document, i.e. a lumened device with attached capsule in which steam penetration is judged by inactivation or survival of a specified biological indicator;
—    an alternative hollow device:
—    employing the same specific test load as defined for the RHD and a chemical indicator designed specifically for use in the reference hollow test load, i.e. a lumened device with an attached capsule in which steam penetration is judged by visual examination of a chemical indicator;
—    equivalent in performance to the RHD, i.e. an alternative hollow device, usually commercially manufactured, of any design.

Nõutud väljad on tähistatud *

*
*
*
PDF
26,84 € koos KM-ga
Paber
26,84 € koos KM-ga
Sirvi standardit alates 2,44 € koos KM-ga
Standardi monitooring

Teised on ostnud veel

Põhitekst

EVS-EN ISO 14644-4:2022

Cleanrooms and associated controlled environments - Part 4: Design, construction and start-up (ISO 14644-4:2022)
Uusim versioon Kehtiv alates 15.12.2022
Põhitekst

EVS-EN 14079:2003

Mitteaktiivsed meditsiiniseadmed. Nõuded ja katsemeetodid absorbeerivale puuvillasele marlile ning absorbeerivale puuvill-viskoosmarlile
Uusim versioon Kehtiv alates 01.06.2003
Põhitekst

EVS-EN ISO 7886-1:2018

Steriilsed ühekordsed süstlad nahaalusteks süsteteks. Osa 1: Süstlad käsitsi kasutamiseks
Uusim versioon Kehtiv alates 16.04.2018
Põhitekst

EVS-EN ISO 11138-1:2017

Tervishoiutoodete steriliseerimine. Bioloogilised indikaatorid. Osa 1: Üldnõuded
Uusim versioon Kehtiv alates 18.04.2017